Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2012 |
Principal Product | Contactors/Relays |
NAICS | 335313 - Switchgear and Switchboard Apparatus Manufacturing |
SIC | 3613 - Switchgear And Switchboard Apparatus |
Sales | $10,000,000-$50,000,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 70,000 |
Annual Production | 70,000 Units |
Production Hrs. Annual | 4,800 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $98,436 | 1,201,600 | kWh | $0.08 |
Electricity Demand | $10,531 | 3,708 | kW-months/year | $2.84 |
Natural Gas | $29,047 | 3,570 | MMBtu | $8.14 |
TOTAL ENERGY COSTS | $146,187 | |||
RECOMMENDED SAVINGS* | $31,692 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $20,944 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $550 Cost: $1,000 |
- | - | - | - | - | - | $550 | 129,404 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$550 129,404 Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $6,519 Cost: $5,000 |
$6,519 | 91,823 | - | - | - | - | - | - | - | - |
$6,519 91,823 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.4151 MINIMIZE WATER USAGE |
Savings: $1,496 Cost: $1,000 |
- | - | - | - | - | - | $766 | 180,268 | $730 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$766 180,268 Tgal |
$730 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $1,458 Cost: - |
$1,458 | 20,480 | - | - | - | - | - | - | - | - |
$1,458 20,480 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $239 Cost: - |
$211 | 2,962 | $28 | 12 | - | - | - | - | - | - |
$211 2,962 kWh |
$28 12 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $3,962 Cost: $1,000 |
- | - | - | - | - | - | $2,029 | 477,224 | $1,933 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$2,029 477,224 Tgal |
$1,933 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $13,543 Cost: - |
$5,672 | 79,563 | $431 | 152 | $7,440 | 914 | - | - | - | - |
$5,672 79,563 kWh |
$431 152 kW-months/year |
$7,440 914 MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $2,209 Cost: $1,000 |
- | - | - | - | $2,209 | 271 | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,209 271 MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7314 REDUCE VENTILATION AIR |
Savings: $882 Cost: $300 |
$223 | 3,133 | $13 | 5 | $646 | 79 | - | - | - | - |
$223 3,133 kWh |
$13 5 kW-months/year |
$646 79 MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $834 Cost: $600 |
$834 | 11,654 | - | - | - | - | - | - | - | - |
$834 11,654 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $31,692 Cost: $9,900 |
$14,917 | 209,615 | $472 | 169 | $10,295 | 1,264 | $3,345 | 786,896 | $2,663 | - | $14,917 209,615 kWh |
$472 169 kW-months/year |
$10,295 1,264 MMBtu |
$3,345 786,896 Tgal |
$2,663 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $20,944 Cost: $5,300 |
$12,414 | 174,519 | $444 | 157 | $8,086 | 993 | - | - | - | - | $12,414 174,519 kWh |
$444 157 kW-months/year |
$8,086 993 MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Water Consumption |