Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2012 |
Principal Product | Infrared Cameras |
NAICS | 334220 - Radio and Television Broadcasting and Wireless Communications Equipment Manufacturing |
SIC | 3663 - Radio & Tv Communications Equipment |
Sales | $100,000,000-$500,000,000 |
# of Employees | 550 |
Plant Area (Sq.Ft.) | 243,000 |
Annual Production | 10,000 Pieces |
Production Hrs. Annual | 3,672 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $791,758 | 15,963,603 | kWh | $0.05 |
Electricity Demand | $383,503 | 32,196 | kW-months/year | $11.91 |
Natural Gas | $237,070 | 41,347 | MMBtu | $5.73 |
TOTAL ENERGY COSTS | $1,524,294 | |||
RECOMMENDED SAVINGS* | $243,998 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $20,166 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $6,307 Cost: $2,925 |
$3,413 | 75,169 | $2,894 | 240 | - | - |
$3,413 75,169 kWh |
$2,894 240 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $6,307 Cost: $2,925 |
$3,413 | 75,169 | $2,894 | 240 | - | - |
$3,413 75,169 kWh |
$2,894 240 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $2,365 Cost: $2,650 |
$1,280 | 28,188 | $1,085 | 96 | - | - |
$1,280 28,188 kWh |
$1,085 96 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $2,365 Cost: $2,650 |
$1,280 | 28,188 | $1,085 | 96 | - | - |
$1,280 28,188 kWh |
$1,085 96 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $5,184 Cost: - |
$5,184 | 114,176 | - | - | - | - |
$5,184 114,176 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $888 Cost: $1,300 |
$655 | 14,420 | $233 | 19 | - | - |
$655 14,420 kWh |
$233 19 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $1,934 Cost: - |
$1,934 | 42,593 | - | - | - | - |
$1,934 42,593 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7233 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT |
Savings: $191,536 Cost: $383,074 |
$66,738 | 1,470,000 | $23,721 | 2,016 | $101,077 | 17,640 |
$66,738 1,470,000 kWh |
$23,721 2,016 kW-months/year |
$101,077 17,640 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL |
Savings: $27,112 Cost: $122,500 |
$20,044 | 441,504 | $7,068 | 605 | - | - |
$20,044 441,504 kWh |
$7,068 605 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $243,998 Cost: $518,024 |
$103,941 | 2,289,407 | $38,980 | 3,312 | $101,077 | 17,640 | $103,941 2,289,407 kWh |
$38,980 3,312 kW-months/year |
$101,077 17,640 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $20,166 Cost: $12,450 |
$11,975 | 263,727 | $8,191 | 691 | - | - | $11,975 263,727 kWh |
$8,191 691 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |