Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2012 |
Principal Product | Flexible Projection Material |
NAICS | 325992 - Photographic Film, Paper, Plate, and Chemical Manufacturing |
SIC | 3861 - Photographic Equipment And Supplies |
Sales | $1,000,000-$5,000,000 |
# of Employees | 27 |
Plant Area (Sq.Ft.) | 43,000 |
Annual Production | 9,000 Thousand Feet |
Production Hrs. Annual | 6,240 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $121,850 | 2,662,507 | kWh | $0.05 |
Electricity Demand | $111,979 | 6,984 | kW-months/year | $16.03 |
Natural Gas | $72,539 | 10,990 | MMBtu | $6.60 |
TOTAL ENERGY COSTS | $306,368 | |||
RECOMMENDED SAVINGS* | $42,426 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $33,693 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $1,385 Cost: $1,660 |
$422 | 9,379 | $963 | 60 | - | - |
$422 9,379 kWh |
$963 60 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $5,228 Cost: $10,000 |
$5,228 | 116,184 | - | - | - | - |
$5,228 116,184 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $4,564 Cost: $16,800 |
$4,564 | 101,430 | - | - | - | - |
$4,564 101,430 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $3,610 Cost: $1,500 |
- | - | - | - | $3,610 | 547 |
- - kWh |
- - kW-months/year |
$3,610 547 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,199 Cost: $1,500 |
$810 | 17,722 | $389 | 24 | - | - |
$810 17,722 kWh |
$389 24 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2113 REPAIR OR REPLACE STEAM TRAPS |
Savings: $10,454 Cost: $1,800 |
- | - | - | - | $10,454 | 1,584 |
- - kWh |
- - kW-months/year |
$10,454 1,584 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2163 USE MINIMUM STEAM OPERATING PRESSURE |
Savings: $7,517 Cost: - |
- | - | - | - | $7,517 | 1,139 |
- - kWh |
- - kW-months/year |
$7,517 1,139 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $2,567 Cost: $4,000 |
$1,529 | 33,969 | $1,038 | 65 | - | - |
$1,529 33,969 kWh |
$1,038 65 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2522 ISOLATE HOT OR COLD EQUIPMENT |
Savings: $1,602 Cost: $4,000 |
$1,602 | 35,604 | - | - | - | - |
$1,602 35,604 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,512 Cost: - |
$1,512 | 33,617 | - | - | - | - |
$1,512 33,617 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $2,788 Cost: $3,000 |
- | - | - | - | $2,788 | 423 |
- - kWh |
- - kW-months/year |
$2,788 423 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $42,426 Cost: $44,260 |
$15,667 | 347,905 | $2,390 | 149 | $24,369 | 3,693 | $15,667 347,905 kWh |
$2,390 149 kW-months/year |
$24,369 3,693 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $33,693 Cost: $19,460 |
$7,972 | 176,902 | $1,352 | 84 | $24,369 | 3,693 | $7,972 176,902 kWh |
$1,352 84 kW-months/year |
$24,369 3,693 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |