Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2019 |
Principal Product | Automotive Alternators and Starter Motors |
NAICS | 336320 - Motor Vehicle Electrical and Electronic Equipment Manufacturing |
SIC | 3694 - Engine Electrical Equipment |
Sales | >$500,000,000 |
# of Employees | 795 |
Plant Area (Sq.Ft.) | 602,941 |
Annual Production | 5,864,908 Units |
Production Hrs. Annual | 7,200 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,618,060 | 29,152,435 | kWh | $0.06 |
Electricity Demand | $324,075 | 57,076 | kW-months/year | $5.68 |
Natural Gas | $320,093 | 58,173 | MMBtu | $5.50 |
TOTAL ENERGY COSTS | $2,320,993 | |||
RECOMMENDED SAVINGS* | $50,026 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $7,453 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $11,762 Cost: - |
- | - | - | - | - | - | $11,762 | 1,435 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$11,762 1,435 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $7,453 Cost: - |
$7,453 | 134,280 | - | - | - | - | - | - |
$7,453 134,280 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $6,465 Cost: $596 |
- | - | - | - | $6,465 | 1,176 | - | - |
- - kWh |
- - kW-months/year |
$6,465 1,176 MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $4,677 Cost: $353 |
$3,996 | 72,000 | $681 | 120 | - | - | - | - |
$3,996 72,000 kWh |
$681 120 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $19,669 Cost: $11,170 |
$16,811 | 302,907 | $2,858 | 504 | - | - | - | - |
$16,811 302,907 kWh |
$2,858 504 kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $50,026 Cost: $12,119 |
$28,260 | 509,187 | $3,539 | 624 | $6,465 | 1,176 | $11,762 | 1,435 | $28,260 509,187 kWh |
$3,539 624 kW-months/year |
$6,465 1,176 MMBtu |
$11,762 1,435 Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $7,453 Cost: - |
$7,453 | 134,280 | - | - | - | - | - | - | $7,453 134,280 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal |