IAC logo
IAC Assessment: UD1006
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UD1006
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Dayton
Assessment Year 2019
Principal Product Automotive Steering Components and CVT Transmission Parts
NAICS 336211 - Motor Vehicle Body Manufacturing
SIC 3714 - Motor Vehicle Parts And Accessories
Sales $100,000,000-$500,000,000
# of Employees 312
Plant Area (Sq.Ft.) 286,518
Annual Production 8,547,586 Pieces
Production Hrs. Annual 6,288
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $861,223 13,030,500 kWh $0.07
Electricity Demand $41,877 2,538 kW-months/year $16.50
Electricity Fees $459,902 - $ -
Natural Gas $206,239 40,559 MMBtu $5.08
TOTAL ENERGY COSTS $1,569,241
RECOMMENDED SAVINGS* $264,687 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $44,647
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT Savings:
$44,647
Cost:
$16,500
$43,013 650,721 $1,634 99 - - $43,013
650,721
kWh
$1,634
99
kW-months/year
-
-
MMBtu
02: 2.2612 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION Savings:
$125,929
Cost:
$30,000
$122,440 1,852,345 $3,489 212 - - $122,440
1,852,345
kWh
$3,489
212
kW-months/year
-
-
MMBtu
03: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD Savings:
$27,201
Cost:
$54,202
$26,447 400,113 $754 46 - - $26,447
400,113
kWh
$754
46
kW-months/year
-
-
MMBtu
04: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$50,796
Cost:
-
$50,796 768,464 - - - - $50,796
768,464
kWh
-
-
kW-months/year
-
-
MMBtu
05: 2.2511 INSULATE BARE EQUIPMENT Savings:
$8,839
Cost:
$3,770
- - - - $8,839 1,740 -
-
kWh
-
-
kW-months/year
$8,839
1,740
MMBtu
06: 2.2442 PREHEAT COMBUSTION AIR WITH WASTE HEAT Savings:
$7,275
Cost:
$16,696
- - - - $7,275 1,432 -
-
kWh
-
-
kW-months/year
$7,275
1,432
MMBtu
TOTAL RECOMMENDED Savings:
$264,687
Cost:
$121,168
$242,696 3,671,643 $5,877 356 $16,114 3,172 $242,696
3,671,643
kWh
$5,877
356
kW-months/year
$16,114
3,172
MMBtu
TOTAL IMPLEMENTED Savings:
$44,647
Cost:
$16,500
$43,013 650,721 $1,634 99 - - $43,013
650,721
kWh
$1,634
99
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas