Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2022 |
Principal Product | Ethyl Alcohol Manufacturing |
NAICS | 325193 - Ethyl Alcohol Manufacturing |
SIC | 2869 - Industrial Organic Chemicals, Nec |
Sales | $100,000,000-$500,000,000 |
# of Employees | 62 |
Plant Area (Sq.Ft.) | 500,000 |
Annual Production | 131,998 Thousand Gallons |
Production Hrs. Annual | 8,400 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $3,573,960 | 89,370,101 | kWh | $0.04 |
Electricity Demand | $409,412 | 141,120 | kW-months/year | $2.90 |
Electricity Fees | $5,562 | - | $ | - |
Natural Gas | $9,579,013 | 3,438,471 | MMBtu | $2.79 |
TOTAL ENERGY COSTS | $13,956,838 | |||
RECOMMENDED SAVINGS* | $526,508 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $73,033 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4113 INSTALL MOTOR VOLTAGE CONTROLLER ON LIGHTLY LOADED MOTORS |
Savings: $58,668 Cost: $25,875 |
$58,668 | 1,470,366 | - | - | - | - | - | - | - | - |
$58,668 1,470,366 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $5,757 Cost: - |
$5,222 | 130,884 | $535 | 184 | - | - | - | - | - | - |
$5,222 130,884 kWh |
$535 184 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $3,018 Cost: $10,000 |
$2,745 | 68,648 | $273 | 94 | - | - | - | - | - | - |
$2,745 68,648 kWh |
$273 94 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $68,929 Cost: $100,000 |
$62,688 | 1,571,115 | $6,241 | 2,152 | - | - | - | - | - | - |
$62,688 1,571,115 kWh |
$6,241 2,152 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT |
Savings: $14,725 Cost: $4,661 |
$12,697 | 318,216 | $2,028 | 700 | - | - | - | - | - | - |
$12,697 318,216 kWh |
$2,028 700 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $4,104 Cost: - |
$3,733 | 93,316 | $371 | 128 | - | - | - | - | - | - |
$3,733 93,316 kWh |
$371 128 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $19,725 Cost: $23,544 |
$14,216 | 355,478 | $1,416 | 488 | - | - | $1,575 | - | $2,518 | - |
$14,216 355,478 kWh |
$1,416 488 kW-months/year |
- - MMBtu |
$1,575 - $ |
$2,518 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $351,582 Cost: $1,000,000 |
- | - | - | - | $351,582 | 126,015 | - | - | - | - |
- - kWh |
- - kW-months/year |
$351,582 126,015 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $526,508 Cost: $1,164,080 |
$159,969 | 4,008,023 | $10,864 | 3,745 | $351,582 | 126,015 | $1,575 | - | $2,518 | - | $159,969 4,008,023 kWh |
$10,864 3,745 kW-months/year |
$351,582 126,015 MMBtu |
$1,575 - $ |
$2,518 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $73,033 Cost: $100,000 |
$66,421 | 1,664,431 | $6,612 | 2,280 | - | - | - | - | - | - | $66,421 1,664,431 kWh |
$6,612 2,280 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Primary Raw Material |