Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Dayton
Assessment Year 2022
Principal Product Water
NAICS 221320 - Sewage Treatment Facilities
SIC 4952 - Sewerage Systems
Sales $10,000,000-$50,000,000
# of Employees 30
Plant Area (Sq.Ft.) 120,000
Annual Production 4,740,302 Thousand Gallons
Production Hrs. Annual 8,760
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $635,981 16,294,680 kWh $0.04
Electricity Demand $268,351 24,792 kW-months/year $10.82
Electricity Fees $31,542 - $ -
TOTAL ENERGY COSTS $937,787
RECOMMENDED SAVINGS* $32,009 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS Savings:
$5,844
Cost:
-
$5,844 149,731 - - $5,844
149,731
kWh
-
-
kW-months/year
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$6,705
Cost:
$30,000
$6,492 171,793 $213 20 $6,492
171,793
kWh
$213
20
kW-months/year
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$540
Cost:
-
$391 10,006 $149 14 $391
10,006
kWh
$149
14
kW-months/year
04: 3.1161 ELIMINATE/REDUCE AN OPERATION Savings:
$213
Cost:
-
$213 5,446 - - $213
5,446
kWh
-
-
kW-months/year
05: 2.7234 USE HEAT PUMP FOR SPACE CONDITIONING Savings:
$18,707
Cost:
$62,108
$18,707 479,291 - - $18,707
479,291
kWh
-
-
kW-months/year
TOTAL RECOMMENDED Savings:
$32,009
Cost:
$92,108
$31,647 816,267 $362 33 $31,647
816,267
kWh
$362
33
kW-months/year
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand