Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2023 |
Principal Product | Steel Pipe and Tubes |
NAICS | 331210 - Iron and Steel Pipe and Tube Manufacturing from Purchased Steel |
SIC | 3317 - Steel Pipe And Tubes |
Sales | $50,000,000-$100,000,000 |
# of Employees | 160 |
Plant Area (Sq.Ft.) | 425,000 |
Annual Production | 54,013,022 Pounds |
Production Hrs. Annual | 6,240 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $383,160 | 7,255,710 | kWh | $0.05 |
Electricity Demand | $475,730 | 31,401 | kW-months/year | $15.15 |
Electricity Fees | $780 | - | $ | - |
Natural Gas | $115,057 | 19,525 | MMBtu | $5.89 |
TOTAL ENERGY COSTS | $993,001 | |||
RECOMMENDED SAVINGS* | $83,235 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $9,026 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $589 Cost: - |
$272 | 5,159 | $317 | 21 | - | - | - | - | - | - |
$272 5,159 kWh |
$317 21 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $12,692 Cost: $430 |
- | - | - | - | $12,692 | 1,419 | - | - | - | - |
- - kWh |
- - kW-months/year |
$12,692 1,419 Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $38,039 Cost: - |
$24,513 | 464,256 | $13,526 | 893 | - | - | - | - | - | - |
$24,513 464,256 kWh |
$13,526 893 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $19,345 Cost: $19,667 |
$7,117 | 134,784 | $11,781 | 778 | - | - | $6 | - | $441 | - |
$7,117 134,784 kWh |
$11,781 778 kW-months/year |
- - Tgal |
$6 - $ |
$441 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,046 Cost: $952 |
$800 | 15,144 | $1,246 | 82 | - | - | - | - | - | - |
$800 15,144 kWh |
$1,246 82 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4324 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT |
Savings: $210 Cost: $741 |
$210 | 3,974 | - | - | - | - | - | - | - | - |
$210 3,974 kWh |
- - kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $6,980 Cost: $2,457 |
$6,980 | 132,198 | - | - | - | - | - | - | - | - |
$6,980 132,198 kWh |
- - kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $3,334 Cost: $3,051 |
$3,334 | 63,141 | - | - | - | - | - | - | - | - |
$3,334 63,141 kWh |
- - kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $83,235 Cost: $27,298 |
$43,226 | 818,656 | $26,870 | 1,774 | $12,692 | 1,419 | $6 | - | $441 | - | $43,226 818,656 kWh |
$26,870 1,774 kW-months/year |
$12,692 1,419 Tgal |
$6 - $ |
$441 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $9,026 Cost: $3,409 |
$7,780 | 147,342 | $1,246 | 82 | - | - | - | - | - | - | $7,780 147,342 kWh |
$1,246 82 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | One-time Revenue or Avoided Cost |