Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 1999
Principal Product Shrimp Processing
NAICS n/a
SIC 2711 - Newspapers
Sales $50,000,000-$100,000,000
# of Employees 450
Plant Area (Sq.Ft.) 90,000
Annual Production 0 Pieces
Production Hrs. Annual 4,420
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $336,730 8,370,164 kWh $0.04
Electricity Demand $170,186 21,252 kW-months/year $8.01
Natural Gas $28,703 4,306 MMBtu $6.67
TOTAL ENERGY COSTS $535,619
RECOMMENDED SAVINGS* $14,508 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $14,508
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Water Disposal Administrative Changes Ancillary Material Cost Electricity Usage Electricity Demand Water Disposal Administrative Changes Ancillary Material Cost
$ kWh $ kW-months/year $ Tgal $ $ $ $
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$983
Cost:
-
$547 7,620 $58 1 - - - - $378 - $547
7,620
kWh
$58
1
kW-months/year
-
-
Tgal
-
-
$
$378
-
$
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$6,086
Cost:
-
$6,086 83,236 - - - - - - - - $6,086
83,236
kWh
-
-
kW-months/year
-
-
Tgal
-
-
$
-
-
$
03: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$184
Cost:
-
$126 3,224 $58 1 - - - - - - $126
3,224
kWh
$58
1
kW-months/year
-
-
Tgal
-
-
$
-
-
$
04: 3.4151 MINIMIZE WATER USAGE Savings:
$566
Cost:
$40
- - - - $566 152,100 - - - - -
-
kWh
-
-
kW-months/year
$566
152,100
Tgal
-
-
$
-
-
$
05: 4.444 INSTALL SYSTEM TO COLLECT SCRAP Savings:
$6,689
Cost:
$12,000
- - - - $189 50,700 $6,500 - - - -
-
kWh
-
-
kW-months/year
$189
50,700
Tgal
$6,500
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$14,508
Cost:
$12,040
$6,759 94,080 $116 2 $755 202,800 $6,500 - $378 - $6,759
94,080
kWh
$116
2
kW-months/year
$755
202,800
Tgal
$6,500
-
$
$378
-
$
TOTAL IMPLEMENTED Savings:
$14,508
Cost:
$12,040
$6,759 94,080 $116 2 $755 202,800 $6,500 - $378 - $6,759
94,080
kWh
$116
2
kW-months/year
$755
202,800
Tgal
$6,500
-
$
$378
-
$
Savings
Cost
$ kWh $ kW-months/year $ Tgal $ $ $ $
Electricity Usage Electricity Demand Water Disposal Administrative Changes Ancillary Material Cost Electricity Usage Electricity Demand Water Disposal Administrative Changes Ancillary Material Cost