Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Louisville
Assessment Year 1999
Principal Product Winches, couplings, trailer jacks
NAICS n/a
SIC 3531 - Construction Machinery
Sales $10,000,000-$50,000,000
# of Employees 75
Plant Area (Sq.Ft.) 110,000
Annual Production 1,062,500 Pieces
Production Hrs. Annual 2,000
Location (State) KY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $48,423 1,569,754 kWh $0.03
Electricity Demand $23,747 5,321 kW-months/year $4.46
Natural Gas $50,135 12,815 MMBtu $3.91
TOTAL ENERGY COSTS $161,048
RECOMMENDED SAVINGS* $80,022 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $62,180
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Solid Waste (non-haz) Personnel Changes One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Solid Waste (non-haz) Personnel Changes One-time Revenue or Avoided Cost
$ kWh $ kW-months/year $ lb $ $ $ $
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,233
Cost:
$20
$734 24,033 $499 112 - - - - - - $734
24,033
kWh
$499
112
kW-months/year
-
-
lb
-
-
$
-
-
$
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$480
Cost:
$131
$323 10,551 $157 35 - - - - - - $323
10,551
kWh
$157
35
kW-months/year
-
-
lb
-
-
$
-
-
$
03: 3.2111 INSTALL REDUNDANT EQUIPMENT TO AVOID LOSSES CAUSED BY EQUIPMENT FAILURE AND ROUTINE MAINTENANCE Savings:
$11,305
Cost:
$800
$2,505 187,866 - - - - $8,800 - - - $2,505
187,866
kWh
-
-
kW-months/year
-
-
lb
$8,800
-
$
-
-
$
04: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS Savings:
$4,824
Cost:
-
- - - - $4,824 230,400 - - - - -
-
kWh
-
-
kW-months/year
$4,824
230,400
lb
-
-
$
-
-
$
05: 4.122 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS Savings:
$62,180
Cost:
$300
- - - - - - - - $62,180 - -
-
kWh
-
-
kW-months/year
-
-
lb
-
-
$
$62,180
-
$
TOTAL RECOMMENDED Savings:
$80,022
Cost:
$1,251
$3,562 222,450 $656 147 $4,824 230,400 $8,800 - $62,180 - $3,562
222,450
kWh
$656
147
kW-months/year
$4,824
230,400
lb
$8,800
-
$
$62,180
-
$
TOTAL IMPLEMENTED Savings:
$62,180
Cost:
$300
- - - - - - - - $62,180 - -
-
kWh
-
-
kW-months/year
-
-
lb
-
-
$
$62,180
-
$
Savings
Cost
$ kWh $ kW-months/year $ lb $ $ $ $