Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Louisville |
---|---|
Assessment Year | 2000 |
Principal Product | Steel Nails, Spikes & Wiredrawing |
NAICS | n/a |
SIC | 3315 - Steel Wire And Related Products |
Sales | n/a |
# of Employees | 83 |
Plant Area (Sq.Ft.) | 300,000 |
Annual Production | 45,000 Tons |
Production Hrs. Annual | 8,568 |
Location (State) | KY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $674,740 | 25,394,783 | kWh | $0.03 |
Electricity Demand | $235,696 | 40,449 | kW-months/year | $5.83 |
Natural Gas | $285,885 | 91,505 | MMBtu | $3.12 |
TOTAL ENERGY COSTS | $1,684,393 | |||
RECOMMENDED SAVINGS* | $34,322 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $12,291 |
#|Description |
Savings Cost |
Status | Electricity Usage | One-time Revenue or Avoided Cost | By-product Production | Electricity Usage | One-time Revenue or Avoided Cost | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $6,743 Cost: - |
- | - | $6,743 | - | - | - |
- - kWh |
$6,743 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7122 DISCONNECT BALLASTS |
Savings: $12,291 Cost: $1,236 |
$12,291 | 462,192 | - | - | - | - |
$12,291 462,192 kWh |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.322 ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL |
Savings: $15,288 Cost: $80,000 |
- | - | - | - | $15,288 | - |
- - kWh |
- - $ |
$15,288 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $34,322 Cost: $81,236 |
$12,291 | 462,192 | $6,743 | - | $15,288 | - | $12,291 462,192 kWh |
$6,743 - $ |
$15,288 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $12,291 Cost: $1,236 |
$12,291 | 462,192 | - | - | - | - | $12,291 462,192 kWh |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||