IAC logo
IAC Assessment: UL2415
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UL2415
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Louisville
Assessment Year 2024
Principal Product Plastic Bottles
NAICS 326160 - Plastics Bottle Manufacturing
SIC 3085 - Plastics Bottles
Sales $10,000,000-$50,000,000
# of Employees 80
Plant Area (Sq.Ft.) 210,000
Annual Production 48,000,000 Pieces
Production Hrs. Annual 6,000
Location (State) IN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $209,083 3,314,888 kWh $0.06
Electricity Demand $159,644 8,939 kW-months/year $17.86
Electricity Fees $17,175 - $ -
Natural Gas $11,058 1,797 MMBtu $6.15
TOTAL ENERGY COSTS $396,960
RECOMMENDED SAVINGS* $279,986 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees Electricity Usage Electricity Demand Electricity Fees
$ kWh $ kW-months/year $ $
01: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$28,874
Cost:
$11,700
- - - - $28,874 - -
-
kWh
-
-
kW-months/year
$28,874
-
$
02: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE Savings:
$72,820
Cost:
-
- - - - $72,820 - -
-
kWh
-
-
kW-months/year
$72,820
-
$
03: 2.2692 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER Savings:
$62,771
Cost:
$58,367
$40,075 635,367 $22,696 1,271 - - $40,075
635,367
kWh
$22,696
1,271
kW-months/year
-
-
$
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$6,257
Cost:
$2,700
$6,257 99,153 - - - - $6,257
99,153
kWh
-
-
kW-months/year
-
-
$
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$4,401
Cost:
$2,438
$4,401 70,311 - - - - $4,401
70,311
kWh
-
-
kW-months/year
-
-
$
06: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$104,863
Cost:
$758,879
$69,697 1,104,561 $35,166 1,968 - - $69,697
1,104,561
kWh
$35,166
1,968
kW-months/year
-
-
$
TOTAL RECOMMENDED Savings:
$279,986
Cost:
$834,084
$120,430 1,909,392 $57,862 3,239 $101,694 - $120,430
1,909,392
kWh
$57,862
3,239
kW-months/year
$101,694
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Electricity Fees Electricity Usage Electricity Demand Electricity Fees