Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Louisville
Assessment Year 2025
Principal Product Thermoplastic Resins
NAICS 325211 - Plastics Material and Resin Manufacturing
SIC 2821 - Plastics Materials And Resins
Sales $100,000,000-$500,000,000
# of Employees 103
Plant Area (Sq.Ft.) 220,000
Annual Production 210,000,000 Pounds
Production Hrs. Annual 4,992
Location (State) KY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,312,657 29,778,960 kWh $0.04
Electricity Demand $899,526 52,913 kW-months/year $17.00
Electricity Fees $206,354 - $ -
Natural Gas $13,462 1,650 MMBtu $8.16
TOTAL ENERGY COSTS $2,431,999
RECOMMENDED SAVINGS* $84,437 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$56,773
Cost:
$527,158
$33,522 760,496 $23,251 1,369 $33,522
760,496
kWh
$23,251
1,369
kW-months/year
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$11,632
Cost:
$24,675
$11,632 263,886 - - $11,632
263,886
kWh
-
-
kW-months/year
03: 2.2692 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER Savings:
$16,032
Cost:
$37,000
$8,312 188,913 $7,720 454 $8,312
188,913
kWh
$7,720
454
kW-months/year
TOTAL RECOMMENDED Savings:
$84,437
Cost:
$588,833
$53,466 1,213,295 $30,971 1,823 $53,466
1,213,295
kWh
$30,971
1,823
kW-months/year
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand