Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Michigan |
---|---|
Assessment Year | 1999 |
Principal Product | Plating and Painting |
NAICS | n/a |
SIC | 3471 - Plating And Polishing |
Sales | $10,000,000-$50,000,000 |
# of Employees | 260 |
Plant Area (Sq.Ft.) | 150,000 |
Annual Production | 300,000,000 Pieces |
Production Hrs. Annual | 8,112 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $439,856 | 8,311,255 | kWh | $0.05 |
Electricity Demand | $11,034 | 600 | kW-months/year | $18.39 |
Electricity Fees | $3,574 | - | $ | - |
Natural Gas | $44,873 | 19,307 | MMBtu | $2.32 |
TOTAL ENERGY COSTS | $499,337 | |||
RECOMMENDED SAVINGS* | $686,687 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $353,580 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $2,000 Cost: $2,000 |
$1,312 | 23,447 | $688 | 38 | - | - | - | - |
$1,312 23,447 kWh |
$688 38 kW-months/year |
- - Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $35,000 Cost: $43,000 |
- | - | - | - | - | - | $35,000 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$35,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.4151 MINIMIZE WATER USAGE |
Savings: $35,600 Cost: $5,500 |
- | - | - | - | $35,600 | 8,000,000 | - | - |
- - kWh |
- - kW-months/year |
$35,600 8,000,000 Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.4114 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER |
Savings: $21,232 Cost: $14,700 |
- | - | - | - | $21,232 | 6,000,000 | - | - |
- - kWh |
- - kW-months/year |
$21,232 6,000,000 Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION |
Savings: $259,748 Cost: $13,300 |
- | - | - | - | $259,748 | 70,000,000 | - | - |
- - kWh |
- - kW-months/year |
$259,748 70,000,000 Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.3132 USE REVERSE OSMOSIS TO CONCENTRATE MATERIAL |
Savings: $307,747 Cost: $800,000 |
- | - | - | - | $307,747 | 97,000,000 | - | - |
- - kWh |
- - kW-months/year |
$307,747 97,000,000 Tgal |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $25,360 Cost: $15,700 |
- | - | - | - | - | - | $25,360 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$25,360 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $686,687 Cost: $894,200 |
$1,312 | 23,447 | $688 | 38 | $624,327 | 181,000,000 | $60,360 | - | $1,312 23,447 kWh |
$688 38 kW-months/year |
$624,327 181,000,000 Tgal |
$60,360 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $353,580 Cost: $78,500 |
$1,312 | 23,447 | $688 | 38 | $316,580 | 84,000,000 | $35,000 | - | $1,312 23,447 kWh |
$688 38 kW-months/year |
$316,580 84,000,000 Tgal |
$35,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Water Disposal | Personnel Changes |