Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Michigan |
---|---|
Assessment Year | 2000 |
Principal Product | Glass Products |
NAICS | n/a |
SIC | 3200 - |
Sales | $10,000,000-$50,000,000 |
# of Employees | 130 |
Plant Area (Sq.Ft.) | 42,000 |
Annual Production | 12,000 Thousand Feet |
Production Hrs. Annual | 7,344 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $172,037 | 5,364,889 | kWh | $0.03 |
Electricity Demand | $158,471 | 17,592 | kW-months/year | $9.01 |
Electricity Fees | $23,307 | - | $ | - |
Natural Gas | $1,814 | 403 | MMBtu | $4.50 |
TOTAL ENERGY COSTS | $355,629 | |||
RECOMMENDED SAVINGS* | $51,700 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $17,500 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Primary Raw Material | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $4,796 Cost: $2,000 |
$4,796 | 69,461 | - | - | - | - | - | - |
$4,796 69,461 kWh |
- - kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,023 Cost: $800 |
$681 | 21,102 | $342 | 35 | - | - | - | - |
$681 21,102 kWh |
$342 35 kW-months/year |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.5211 REUSE SCRAP GLASS AS FEED STOCK |
Savings: $7,831 Cost: - |
- | - | - | - | $7,831 | 148,500 | - | - |
- - kWh |
- - kW-months/year |
$7,831 148,500 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.5311 RECOVER AND REUSE WASTE MATERIAL |
Savings: $17,500 Cost: $1,000 |
- | - | - | - | $17,500 | 90,000 | - | - |
- - kWh |
- - kW-months/year |
$17,500 90,000 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.421 MODIFY CURRENT INCENTIVE PROGRAM |
Savings: $20,550 Cost: $32,800 |
- | - | - | - | - | - | $20,550 | - |
- - kWh |
- - kW-months/year |
- - lb |
$20,550 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $51,700 Cost: $36,600 |
$5,477 | 90,563 | $342 | 35 | $25,331 | 238,500 | $20,550 | - | $5,477 90,563 kWh |
$342 35 kW-months/year |
$25,331 238,500 lb |
$20,550 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $17,500 Cost: $1,000 |
- | - | - | - | $17,500 | 90,000 | - | - | - - kWh |
- - kW-months/year |
$17,500 90,000 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Primary Raw Material | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Primary Raw Material |