Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Michigan |
---|---|
Assessment Year | 2001 |
Principal Product | Reconstituted Wood Products |
NAICS | n/a |
SIC | 2493 - Reconstituted Wood Products |
Sales | $50,000,000-$100,000,000 |
# of Employees | 193 |
Plant Area (Sq.Ft.) | 400,000 |
Annual Production | 270,000 Thousand Feet |
Production Hrs. Annual | 6,000 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $2,103,630 | 81,200,763 | kWh | $0.03 |
Electricity Demand | $445,198 | 136,980 | kW-months/year | $3.25 |
Electricity Fees | $597,421 | - | $ | - |
Natural Gas | $1,103,570 | 271,749 | MMBtu | $4.06 |
TOTAL ENERGY COSTS | $4,249,819 | |||
RECOMMENDED SAVINGS* | $102,300 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $87,250 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $8,250 Cost: $3,000 |
$3,291 | 111,340 | $4,959 | 348 | - | - | - | - |
$3,291 111,340 kWh |
$4,959 348 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $3,900 Cost: $15,000 |
$3,900 | 100,792 | - | - | - | - | - | - |
$3,900 100,792 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $1,550 Cost: $1,600 |
- | - | - | - | $1,550 | 381 | - | - |
- - kWh |
- - kW-months/year |
$1,550 381 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $25,000 Cost: $13,700 |
- | - | - | - | $25,000 | 5,288 | - | - |
- - kWh |
- - kW-months/year |
$25,000 5,288 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1221 REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES |
Savings: $56,800 Cost: $75,000 |
- | - | - | - | $56,800 | 14,000 | - | - |
- - kWh |
- - kW-months/year |
$56,800 14,000 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.632 CHANGE OPERATING CONDITIONS |
Savings: $6,800 Cost: $11,000 |
- | - | - | - | - | - | $6,800 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$6,800 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $102,300 Cost: $119,300 |
$7,191 | 212,132 | $4,959 | 348 | $83,350 | 19,669 | $6,800 | - | $7,191 212,132 kWh |
$4,959 348 kW-months/year |
$83,350 19,669 MMBtu |
$6,800 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $87,250 Cost: $105,300 |
$3,900 | 100,792 | - | - | $83,350 | 19,669 | - | - | $3,900 100,792 kWh |
- - kW-months/year |
$83,350 19,669 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | One-time Revenue or Avoided Cost |