Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Michigan |
---|---|
Assessment Year | 2006 |
Principal Product | Automotive Climate Control Assemblies |
NAICS | 336390 - Other Motor Vehicle Parts Manufacturing |
SIC | 3585 - Refrigeration And Heating Equipment |
Sales | n/a |
# of Employees | 1,500 |
Plant Area (Sq.Ft.) | 1,000,000 |
Annual Production | 0 Pieces |
Production Hrs. Annual | 7,488 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,128,000 | 43,352,400 | kWh | $0.03 |
Electricity Demand | $1,092,107 | 85,420 | kW-months/year | $12.79 |
Electricity Fees | $49,132 | - | $ | - |
Natural Gas | $1,526,362 | 170,163 | MMBtu | $8.97 |
TOTAL ENERGY COSTS | $3,795,601 | |||
RECOMMENDED SAVINGS* | $135,839 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $17,436 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $62,424 Cost: $69,750 |
$(-2,123) | (-81,592) | $(-1,903) | (-149) | $66,450 | 7,408 |
$(-2,123) (-81,592) kWh |
$(-1,903) (-149) kW-months/year |
$66,450 7,408 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3112 STORE HEATED/ COOLED WATER FOR USE DURING PEAK DEMAND PERIODS |
Savings: $30,865 Cost: $25,000 |
- | - | $30,865 | 2,413 | - | - |
- - kWh |
$30,865 2,413 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS |
Savings: $12,963 Cost: $2,480 |
- | - | - | - | $12,963 | 1,599 |
- - kWh |
- - kW-months/year |
$12,963 1,599 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $12,296 Cost: $7,000 |
$6,880 | 264,428 | $5,416 | 424 | - | - |
$6,880 264,428 kWh |
$5,416 424 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $9,136 Cost: $3,084 |
- | - | - | - | $9,136 | 1,018 |
- - kWh |
- - kW-months/year |
$9,136 1,018 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $4,473 Cost: $400 |
$4,473 | 171,924 | - | - | - | - |
$4,473 171,924 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $2,953 Cost: $3,286 |
- | - | - | - | $2,953 | 329 |
- - kWh |
- - kW-months/year |
$2,953 329 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $596 Cost: $660 |
$596 | 11,464 | - | - | - | - |
$596 11,464 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $133 Cost: $175 |
$133 | 5,107 | - | - | - | - |
$133 5,107 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $135,839 Cost: $111,835 |
$9,959 | 371,331 | $34,378 | 2,688 | $91,502 | 10,354 | $9,959 371,331 kWh |
$34,378 2,688 kW-months/year |
$91,502 10,354 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $17,436 Cost: $2,880 |
$4,473 | 171,924 | - | - | $12,963 | 1,599 | $4,473 171,924 kWh |
- - kW-months/year |
$12,963 1,599 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |