Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Michigan |
---|---|
Assessment Year | 2010 |
Principal Product | Fuel Fittings, Custom Fittings, Machined Parts, Plastic Injection Molded |
NAICS | 333249 - Other Industrial Machinery Manufacturing |
SIC | 3492 - Fluid Power Valves & Hose Fittings |
Sales | $10,000,000-$50,000,000 |
# of Employees | 125 |
Plant Area (Sq.Ft.) | 90,000 |
Annual Production | 1 Units |
Production Hrs. Annual | 5,125 |
Location (State) | MI |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $249,959 | 3,151,300 | kWh | $0.08 |
Electricity Demand | $30,675 | 9,586 | kW-months/year | $3.20 |
Natural Gas | $33,108 | 3,057 | MMBtu | $10.83 |
TOTAL ENERGY COSTS | $313,742 | |||
RECOMMENDED SAVINGS* | $38,845 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $24,537 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA |
Savings: $10,083 Cost: $500 |
- | - | - | - | $10,083 | 931 |
- - kWh |
- - kW-months/year |
$10,083 931 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $9,498 Cost: $10,000 |
- | - | - | - | $9,498 | 877 |
- - kWh |
- - kW-months/year |
$9,498 877 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $7,516 Cost: $500 |
- | - | - | - | $7,516 | 695 |
- - kWh |
- - kW-months/year |
$7,516 695 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $6,792 Cost: $200 |
$6,206 | 78,246 | $586 | 183 | - | - |
$6,206 78,246 kWh |
$586 183 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $2,241 Cost: $1,000 |
$2,049 | 25,833 | $192 | 60 | - | - |
$2,049 25,833 kWh |
$192 60 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $2,173 Cost: $1,375 |
- | - | - | - | $2,173 | 201 |
- - kWh |
- - kW-months/year |
$2,173 201 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $542 Cost: $1,568 |
- | - | - | - | $542 | 50 |
- - kWh |
- - kW-months/year |
$542 50 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $38,845 Cost: $15,143 |
$8,255 | 104,079 | $778 | 243 | $29,812 | 2,754 | $8,255 104,079 kWh |
$778 243 kW-months/year |
$29,812 2,754 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $24,537 Cost: $14,443 |
$2,049 | 25,833 | $192 | 60 | $22,296 | 2,059 | $2,049 25,833 kWh |
$192 60 kW-months/year |
$22,296 2,059 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |