IAC logo
IAC Assessment: UM0438
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UM0438
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Michigan
Assessment Year 2013
Principal Product Hydrolic fittings coating
NAICS 332813 - Electroplating, Plating, Polishing, Anodizing, and Coloring
SIC 3471 - Plating And Polishing
Sales $5,000,000-$10,000,000
# of Employees 65
Plant Area (Sq.Ft.) 27,000
Annual Production 85,000,000 Pieces
Production Hrs. Annual 4,000
Location (State) IN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $227,000 2,600,000 kWh $0.09
Natural Gas $47,000 6,000 MMBtu $7.83
TOTAL ENERGY COSTS $274,000
RECOMMENDED SAVINGS* $123,858 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$2,260
Cost:
$350
$2,260 26,589 - - $2,260
26,589
kWh
-
-
MMBtu
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$945
Cost:
$600
$945 10,738 - - $945
10,738
kWh
-
-
MMBtu
03: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$22,608
Cost:
$7,500
$34,496 392,000 $(-11,888) (-1,509) $34,496
392,000
kWh
$(-11,888)
(-1,509)
MMBtu
04: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT Savings:
$98,045
Cost:
$175,000
$173,302 1,956,000 $(-75,257) (-9,554) $173,302
1,956,000
kWh
$(-75,257)
(-9,554)
MMBtu
TOTAL RECOMMENDED Savings:
$123,858
Cost:
$183,450
$211,003 2,385,327 $(-87,145) (-11,063) $211,003
2,385,327
kWh
$(-87,145)
(-11,063)
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas