Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Michigan
Assessment Year 2017
Principal Product Steel framed hospitality seating
NAICS 337127 - Institutional Furniture Manufacturing
SIC 2531 - Public Building & Related Furniture
Sales $50,000,000-$100,000,000
# of Employees 292
Plant Area (Sq.Ft.) 226,000
Annual Production 392,586 Pieces
Production Hrs. Annual 5,000
Location (State) MI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $185,301 3,487,469 kWh $0.05
Electricity Demand $162,958 8,446 kW-months/year $19.29
Natural Gas $148,213 25,696 MMBtu $5.77
TOTAL ENERGY COSTS $496,472
RECOMMENDED SAVINGS* $32,511 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$4,743
Cost:
$3,000
$4,743 89,484 - - $4,743
89,484
kWh
-
-
MMBtu
02: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$3,643
Cost:
$5,000
$3,643 68,731 - - $3,643
68,731
kWh
-
-
MMBtu
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$21,737
Cost:
$20,000
$21,737 410,135 - - $21,737
410,135
kWh
-
-
MMBtu
04: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$989
Cost:
$3,700
- - $989 171 -
-
kWh
$989
171
MMBtu
05: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$1,399
Cost:
$325
- - $1,399 242 -
-
kWh
$1,399
242
MMBtu
TOTAL RECOMMENDED Savings:
$32,511
Cost:
$32,025
$30,123 568,350 $2,388 413 $30,123
568,350
kWh
$2,388
413
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas