IAC logo
IAC Assessment: UMS010
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UMS010
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Michigan
Assessment Year 2012
Principal Product Specialty Alloys
NAICS 331513 - Steel Foundries (except Investment)
SIC 3312 - Blast Furnaces And Steel Mills
Sales $1,000,000-$5,000,000
# of Employees 100
Plant Area (Sq.Ft.) 100,000
Annual Production 10,000 Tons
Production Hrs. Annual 3,120
Location (State) MI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $2,460,000 31,868,000 kWh $0.08
Natural Gas $593,000 96,000 MMBtu $6.18
TOTAL ENERGY COSTS $3,053,000
RECOMMENDED SAVINGS* $72,000 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$46,000
Cost:
$85,000
- - $46,000 7,500 -
-
kWh
$46,000
7,500
MMBtu
02: 2.1135 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY Savings:
$16,000
Cost:
$10,000
$16,000 210,000 - - $16,000
210,000
kWh
-
-
MMBtu
03: 3.4115 RECOVER AND REUSE COOLING WATER Savings:
$10,000
Cost:
$20,000
- - $10,000 1,600 -
-
kWh
$10,000
1,600
MMBtu
TOTAL RECOMMENDED Savings:
$72,000
Cost:
$115,000
$16,000 210,000 $56,000 9,100 $16,000
210,000
kWh
$56,000
9,100
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas