Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Michigan
Assessment Year 2012
Principal Product Molten aluminum
NAICS 331318 - Other Aluminum Rolling, Drawing, and Extruding
SIC 3354 - Aluminum Extruded Products
Sales $10,000,000-$50,000,000
# of Employees 100
Plant Area (Sq.Ft.) 100,000
Annual Production 10,000 Pieces
Production Hrs. Annual 7,200
Location (State) MI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $747,267 7,472,670 kWh $0.10
Natural Gas $2,804,008 547,063 MMBtu $5.13
TOTAL ENERGY COSTS $3,551,275
RECOMMENDED SAVINGS* $1,701,000 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$320,000
Cost:
$600,000
- - $320,000 62,000 -
-
kWh
$320,000
62,000
MMBtu
02: 2.1213 DIRECT WARMEST AIR TO COMBUSTION INTAKE Savings:
$106,000
Cost:
$200,000
- - $106,000 20,600 -
-
kWh
$106,000
20,600
MMBtu
03: 2.3416 USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST Savings:
$673,000
Cost:
$1,000,000
$673,000 6,750,000 - - $673,000
6,750,000
kWh
-
-
MMBtu
04: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$465,000
Cost:
$700,000
- - $465,000 90,750 -
-
kWh
$465,000
90,750
MMBtu
05: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$137,000
Cost:
-
- - $137,000 26,700 -
-
kWh
$137,000
26,700
MMBtu
TOTAL RECOMMENDED Savings:
$1,701,000
Cost:
$2,500,000
$673,000 6,750,000 $1,028,000 200,050 $673,000
6,750,000
kWh
$1,028,000
200,050
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas