Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Utah
Assessment Year 2004
Principal Product tables and chairs
NAICS 337127 - Institutional Furniture Manufacturing
SIC 3714 - Motor Vehicle Parts And Accessories
Sales $50,000,000-$100,000,000
# of Employees 310
Plant Area (Sq.Ft.) 30,000
Annual Production 31,875,000 Pieces
Production Hrs. Annual 4,420
Location (State) UT
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $91,486 3,298,330 kWh $0.03
Electricity Demand $102,198 11,859 kW-months/year $8.62
Electricity Fees $39,964 - $ -
Natural Gas $141,648 29,433 MMBtu $4.81
TOTAL ENERGY COSTS $375,296
RECOMMENDED SAVINGS* $53,671 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $34,573
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Ancillary Material Cost
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.2523 REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS Savings:
$21,193
Cost:
$325
- - - - $21,193 3,868 - - -
-
kWh
-
-
kW-months/year
$21,193
3,868
MMBtu
-
-
$
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$8,711
Cost:
$3,315
$(-396) (-12,994) $(-383) (-43) $9,490 1,732 - - $(-396)
(-12,994)
kWh
$(-383)
(-43)
kW-months/year
$9,490
1,732
MMBtu
-
-
$
03: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$5,381
Cost:
$7,500
$(-113) (-3,701) $(-53) (-6) $5,547 1,013 - - $(-113)
(-3,701)
kWh
$(-53)
(-6)
kW-months/year
$5,547
1,013
MMBtu
-
-
$
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$5,006
Cost:
$8,929
- - - - $5,006 914 - - -
-
kWh
-
-
kW-months/year
$5,006
914
MMBtu
-
-
$
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,004
Cost:
$244
$562 18,436 $442 50 - - - - $562
18,436
kWh
$442
50
kW-months/year
-
-
MMBtu
-
-
$
06: 2.6127 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT Savings:
$12,376
Cost:
$1,292
- - - - - - $12,376 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$12,376
-
$
TOTAL RECOMMENDED Savings:
$53,671
Cost:
$21,605
$53 1,741 $6 1 $41,236 7,527 $12,376 - $53
1,741
kWh
$6
1
kW-months/year
$41,236
7,527
MMBtu
$12,376
-
$
TOTAL IMPLEMENTED Savings:
$34,573
Cost:
$1,861
$562 18,436 $442 50 $21,193 3,868 $12,376 - $562
18,436
kWh
$442
50
kW-months/year
$21,193
3,868
MMBtu
$12,376
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Ancillary Material Cost