Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Utah |
---|---|
Assessment Year | 2005 |
Principal Product | undergarments |
NAICS | 315240 - Women’s, Girls’, and Infants’ Cut and Sew Apparel Manufacturing |
SIC | 2341 - Women's, Misses', Children's, and Infants' Underwear and Nightwear |
Sales | $10,000,000-$50,000,000 |
# of Employees | 250 |
Plant Area (Sq.Ft.) | 316,000 |
Annual Production | 2,000,000 Pieces |
Production Hrs. Annual | 2,800 |
Location (State) | UT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $94,461 | 3,405,600 | kWh | $0.03 |
Electricity Demand | $120,569 | 11,902 | kW-months/year | $10.13 |
Natural Gas | $83,086 | 12,864 | MMBtu | $6.46 |
TOTAL ENERGY COSTS | $298,116 | |||
RECOMMENDED SAVINGS* | $64,590 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $11,810 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $1,110 Cost: $4,290 |
- | - | $1,110 | 114 | - | - |
- - kWh |
$1,110 114 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2442 PREHEAT COMBUSTION AIR WITH WASTE HEAT |
Savings: $1,820 Cost: $1,500 |
- | - | - | - | $1,820 | 260 |
- - kWh |
- - kW-months/year |
$1,820 260 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $17,940 Cost: $21,000 |
- | - | - | - | $17,940 | 2,525 |
- - kWh |
- - kW-months/year |
$17,940 2,525 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7229 AIR CONDITION ONLY SPACE NECESSARY |
Savings: $33,020 Cost: $2,085 |
$19,270 | 636,410 | $13,750 | 1,416 | - | - |
$19,270 636,410 kWh |
$13,750 1,416 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $10,700 Cost: $2,000 |
- | - | - | - | $10,700 | 1,510 |
- - kWh |
- - kW-months/year |
$10,700 1,510 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $64,590 Cost: $30,875 |
$19,270 | 636,410 | $14,860 | 1,530 | $30,460 | 4,295 | $19,270 636,410 kWh |
$14,860 1,530 kW-months/year |
$30,460 4,295 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $11,810 Cost: $6,290 |
- | - | $1,110 | 114 | $10,700 | 1,510 | - - kWh |
$1,110 114 kW-months/year |
$10,700 1,510 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |