Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Utah |
---|---|
Assessment Year | 2019 |
Principal Product | Treated water |
NAICS | 221310 - Water Supply and Irrigation Systems |
SIC | 4952 - Sewerage Systems |
Sales | $1,000,000-$5,000,000 |
# of Employees | 10 |
Plant Area (Sq.Ft.) | 25,000 |
Annual Production | 3,650,000 Units |
Production Hrs. Annual | 8,760 |
Location (State) | UT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $136,368 | 3,154,800 | kWh | $0.04 |
Electricity Demand | $66,758 | 5,868 | kW-months/year | $11.38 |
Natural Gas | $37,959 | 5,415 | MMBtu | $7.01 |
TOTAL ENERGY COSTS | $241,085 | |||
RECOMMENDED SAVINGS* | $96,968 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $20,021 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $48,728 Cost: $423,632 |
$33,253 | 769,202 | $24,226 | 2,129 | - | - | $(-8,750) | - | - | - | - | - |
$33,253 769,202 kWh |
$24,226 2,129 kW-months/year |
- - MMBtu |
$(-8,750) - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT |
Savings: $14,902 Cost: $205,000 |
$10,639 | 246,099 | $4,263 | 375 | - | - | - | - | - | - | - | - |
$10,639 246,099 kWh |
$4,263 375 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3417 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT |
Savings: $22,776 Cost: $146,977 |
$24,615 | 569,400 | $8,876 | 780 | $(-6,161) | (-3,020) | - | - | - | - | $(-4,555) | - |
$24,615 569,400 kWh |
$8,876 780 kW-months/year |
$(-6,161) (-3,020) MMBtu |
- - $ |
- - $ |
$(-4,555) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $5,443 Cost: $502 |
- | - | - | - | $5,443 | 776 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$5,443 776 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.8113 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER |
Savings: $2,777 Cost: $6,500 |
- | - | - | - | - | - | - | - | $2,777 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$2,777 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $899 Cost: $2,019 |
$930 | 21,510 | $612 | 54 | $(-643) | (-92) | - | - | - | - | - | - |
$930 21,510 kWh |
$612 54 kW-months/year |
$(-643) (-92) MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.1133 ADJUST BURNERS FOR EFFICIENT OPERATION |
Savings: $1,444 Cost: $400 |
- | - | - | - | $1,444 | 206 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,444 206 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $96,968 Cost: $785,030 |
$69,437 | 1,606,211 | $37,977 | 3,337 | $83 | (-2,130) | $(-8,750) | - | $2,777 | - | $(-4,555) | - | $69,437 1,606,211 kWh |
$37,977 3,337 kW-months/year |
$83 (-2,130) MMBtu |
$(-8,750) - $ |
$2,777 - $ |
$(-4,555) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $20,021 Cost: $213,919 |
$11,569 | 267,609 | $4,875 | 428 | $801 | 114 | - | - | $2,777 | - | - | - | $11,569 267,609 kWh |
$4,875 428 kW-months/year |
$801 114 MMBtu |
- - $ |
$2,777 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost |