Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Utah |
---|---|
Assessment Year | 2021 |
Principal Product | Renewable Natural Gas |
NAICS | 562219 - Other Nonhazardous Waste Treatment and Disposal |
SIC | 4953 - Refuse Systems |
Sales | $1,000,000-$5,000,000 |
# of Employees | 15 |
Plant Area (Sq.Ft.) | 376,000 |
Annual Production | 180,000 Units |
Production Hrs. Annual | 8,760 |
Location (State) | UT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $124,877 | 3,410,075 | kWh | $0.04 |
Electricity Demand | $200,380 | 12,464 | kW-months/year | $16.08 |
Electricity Fees | $14,342 | - | $ | - |
Natural Gas | $104,366 | 30,423 | MMBtu | $3.43 |
TOTAL ENERGY COSTS | $443,965 | |||
RECOMMENDED SAVINGS* | $833,670 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $663,886 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Primary Product | Increase in Production | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Primary Product | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.6125 SELL COMBUSTIBLE WASTE |
Savings: $358,314 Cost: $840,585 |
$(-55,247) | (-1,508,667) | $(-33,226) | (-2,067) | $(-142,348) | (-41,501) | - | - | $589,135 | - | - | - |
$(-55,247) (-1,508,667) kWh |
$(-33,226) (-2,067) kW-months/year |
$(-142,348) (-41,501) MMBtu |
- - $ |
$589,135 - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 4.663 LEVEL TWO – INSTALL CONTROL SYSTEM USING IIOT DEVICES WITH COMMUNICATION CAPABILITIES TO STORE DATA TO THE CLOUD |
Savings: $301,212 Cost: $427,040 |
- | - | - | - | - | - | - | - | - | - | $301,212 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
$301,212 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3417 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT |
Savings: $94,872 Cost: $621,000 |
$96,237 | 2,628,000 | $57,877 | 3,600 | $(-32,962) | (-9,610) | $(-26,280) | - | - | - | - | - |
$96,237 2,628,000 kWh |
$57,877 3,600 kW-months/year |
$(-32,962) (-9,610) MMBtu |
$(-26,280) - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $69,301 Cost: $172,000 |
- | - | - | - | $(-42,652) | (-12,435) | - | - | - | - | $111,953 | - |
- - kWh |
- - kW-months/year |
$(-42,652) (-12,435) MMBtu |
- - $ |
- - $ |
$111,953 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $5,611 Cost: $2,229 |
- | - | - | - | $5,611 | 1,518 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$5,611 1,518 MMBtu |
- - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $4,360 Cost: $920 |
$4,360 | 119,063 | - | - | - | - | - | - | - | - | - | - |
$4,360 119,063 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $833,670 Cost: $2,063,774 |
$45,350 | 1,238,396 | $24,651 | 1,533 | $(-212,351) | (-62,028) | $(-26,280) | - | $589,135 | - | $413,165 | - | $45,350 1,238,396 kWh |
$24,651 1,533 kW-months/year |
$(-212,351) (-62,028) MMBtu |
$(-26,280) - $ |
$589,135 - $ |
$413,165 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $663,886 Cost: $1,268,545 |
$(-50,887) | (-1,389,604) | $(-33,226) | (-2,067) | $(-142,348) | (-41,501) | - | - | $589,135 | - | $301,212 | - | $(-50,887) (-1,389,604) kWh |
$(-33,226) (-2,067) kW-months/year |
$(-142,348) (-41,501) MMBtu |
- - $ |
$589,135 - $ |
$301,212 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Primary Product | Increase in Production | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Primary Product | Increase in Production |