Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Utah |
---|---|
Assessment Year | 2025 |
Principal Product | Surface Finishing |
NAICS | 332812 - Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers |
SIC | 3479 - Metal Coating And Allied Services |
Sales | $10,000,000-$50,000,000 |
# of Employees | 65 |
Plant Area (Sq.Ft.) | 59,000 |
Annual Production | 1,343 Thousand Feet |
Production Hrs. Annual | 4,832 |
Location (State) | UT |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $23,420 | 658,320 | kWh | $0.04 |
Electricity Demand | $47,093 | 2,914 | kW-months/year | $16.16 |
Electricity Fees | $11,287 | - | $ | - |
Natural Gas | $79,768 | 7,072 | MMBtu | $11.28 |
Fuel Oil #2 | $71,966 | 2,692 | MMBtu | $26.74 |
Other Gas | $6,118 | 1 | MMBtu | $6,117.52 |
TOTAL ENERGY COSTS | $239,652 | |||
RECOMMENDED SAVINGS* | $79,661 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4225 INSTALL COMMON HEADER ON COMPRESSORS |
Savings: $7,583 Cost: $46,630 |
$630 | 17,510 | $617 | 38 | - | - | $6,336 | 237 | - | - |
$630 17,510 kWh |
$617 38 kW-months/year |
- - MMBtu |
$6,336 237 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $7,105 Cost: $5,100 |
- | - | - | - | $7,105 | 630 | - | - | - | - |
- - kWh |
- - kW-months/year |
$7,105 630 MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7492 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE |
Savings: $1,365 Cost: $1,730 |
- | - | - | - | $1,365 | 121 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,365 121 MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $1,805 Cost: $8,150 |
- | - | - | - | $1,805 | 160 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,805 160 MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1131 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC |
Savings: $3,948 Cost: $2,110 |
- | - | - | - | $3,948 | 350 | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,948 350 MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.8113 PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER |
Savings: $4,840 Cost: $11,200 |
- | - | - | - | - | - | - | - | $4,840 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
$4,840 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $5,270 Cost: $7,380 |
$5,270 | 148,090 | - | - | - | - | - | - | - | - |
$5,270 148,090 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $945 Cost: $3,580 |
$591 | 16,600 | $354 | 22 | - | - | - | - | - | - |
$591 16,600 kWh |
$354 22 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $3,940 Cost: $9,000 |
- | - | - | - | - | - | - | - | $3,940 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
$3,940 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.8123 PAY UTILITY BILLS ON TIME |
Savings: $1,860 Cost: $1,500 |
- | - | - | - | - | - | - | - | $1,860 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
$1,860 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $8,090 Cost: $5,000 |
- | - | - | - | - | - | - | - | $8,090 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
$8,090 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.1321 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT |
Savings: $32,910 Cost: $158,576 |
$(-14,310) | (-402,100) | $(-41,510) | (-2,569) | - | - | $50,330 | 1,884 | $38,400 | - |
$(-14,310) (-402,100) kWh |
$(-41,510) (-2,569) kW-months/year |
- - MMBtu |
$50,330 1,884 MMBtu |
$38,400 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $79,661 Cost: $259,956 |
$(-7,819) | (-219,900) | $(-40,539) | (-2,509) | $14,223 | 1,261 | $56,666 | 2,121 | $57,130 | - | $(-7,819) (-219,900) kWh |
$(-40,539) (-2,509) kW-months/year |
$14,223 1,261 MMBtu |
$56,666 2,121 MMBtu |
$57,130 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Fuel Oil #2 | Administrative Changes |