Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Utah |
---|---|
Assessment Year | 2025 |
Principal Product | Petroleum products |
NAICS | 324110 - Petroleum Refineries |
SIC | 2911 - Petroleum Refining |
Sales | $10,000,000-$50,000,000 |
# of Employees | 20 |
Plant Area (Sq.Ft.) | 1,311,000 |
Annual Production | 162,500 Units |
Production Hrs. Annual | 8,760 |
Location (State) | NV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $77,063 | 1,595,700 | kWh | $0.05 |
Electricity Demand | $47,749 | 3,917 | kW-months/year | $12.19 |
Electricity Fees | $21,807 | - | $ | - |
Fuel Oil #4 | $1,236,778 | 130,794 | MMBtu | $9.46 |
TOTAL ENERGY COSTS | $1,383,397 | |||
RECOMMENDED SAVINGS* | $272,260 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Fuel Oil #4 | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Fuel Oil #4 | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8124 Hire Energy Manager |
Savings: $66,000 Cost: $13,000 |
$6,900 | 144,000 | - | - | - | - | $111,100 | 11,800 | $(-52,000) | - |
$6,900 144,000 kWh |
- - kW-months/year |
- - $ |
$111,100 11,800 MMBtu |
$(-52,000) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $31,500 Cost: $18,800 |
- | - | - | - | - | - | $31,500 | 3,330 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$31,500 3,330 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1241 REDUCE EXCESSIVE BOILER BLOWDOWN |
Savings: $20,800 Cost: $16,300 |
- | - | - | - | - | - | $20,800 | 2,200 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$20,800 2,200 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1243 USE HEAT FROM BOILER BLOWDOWN TO PREHEAT BOILER FEED WATER |
Savings: $54,700 Cost: $110,000 |
- | - | - | - | - | - | $54,700 | 5,780 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$54,700 5,780 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $9,950 Cost: $23,600 |
$7,390 | 154,000 | $2,560 | 210 | - | - | - | - | - | - |
$7,390 154,000 kWh |
$2,560 210 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $4,170 Cost: $26,600 |
$3,090 | 64,400 | $1,080 | 89 | - | - | - | - | - | - |
$3,090 64,400 kWh |
$1,080 89 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $62,900 Cost: $32,400 |
- | - | - | - | - | - | $62,900 | 6,650 | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$62,900 6,650 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $890 Cost: $410 |
$656 | 13,600 | $234 | 19 | - | - | - | - | - | - |
$656 13,600 kWh |
$234 19 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $18,600 Cost: $207,000 |
$18,600 | 387,000 | - | - | - | - | - | - | - | - |
$18,600 387,000 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 4.821 PAY BILLS ON TIME TO AVOID LATE FEES |
Savings: $1,500 Cost: $600 |
- | - | - | - | $1,500 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,500 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $1,250 Cost: $11,200 |
- | - | - | - | $1,250 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,250 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $272,260 Cost: $459,910 |
$36,636 | 763,000 | $3,874 | 318 | $2,750 | - | $281,000 | 29,760 | $(-52,000) | - | $36,636 763,000 kWh |
$3,874 318 kW-months/year |
$2,750 - $ |
$281,000 29,760 MMBtu |
$(-52,000) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Fuel Oil #4 | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Fuel Oil #4 | Personnel Changes |