Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Washington
Assessment Year 2023
Principal Product Kitchen and Bath cabinets
NAICS 337110 - Wood Kitchen Cabinet and Countertop Manufacturing
SIC 2434 - Wood Kitchen Cabinets
Sales $50,000,000-$100,000,000
# of Employees 242
Plant Area (Sq.Ft.) 276,000
Annual Production 85,600 Units
Production Hrs. Annual 2,210
Location (State) WA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $257,884 3,712,800 kWh $0.07
Electricity Demand $91,287 13,378 kW-months/year $6.82
Electricity Fees $21,351 - $ -
Natural Gas $181,958 17,395 MMBtu $10.46
TOTAL ENERGY COSTS $763,780
RECOMMENDED SAVINGS* $256,439 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$3,943
Cost:
$30,989
$819 11,781 $436 64 $2,688 257 $819
11,781
kWh
$436
64
kW-months/year
$2,688
257
MMBtu
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$2,868
Cost:
$20
$1,871 26,923 $997 146 - - $1,871
26,923
kWh
$997
146
kW-months/year
-
-
MMBtu
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$2,841
Cost:
$1,520
$2,260 32,513 $581 85 - - $2,260
32,513
kWh
$581
85
kW-months/year
-
-
MMBtu
04: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$236,659
Cost:
$2,614,888
$131,911 1,898,002 $104,748 10,848 - - $131,911
1,898,002
kWh
$104,748
10,848
kW-months/year
-
-
MMBtu
05: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$10,128
Cost:
$13,235
- - $10,128 1,485 - - -
-
kWh
$10,128
1,485
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$256,439
Cost:
$2,660,652
$136,861 1,969,219 $116,890 12,628 $2,688 257 $136,861
1,969,219
kWh
$116,890
12,628
kW-months/year
$2,688
257
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas