Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 2012
Principal Product Traffic and Parking Safety products and Accessories
NAICS 339950 - Sign Manufacturing
SIC 3993 - Signs And Advertising Specialities
Sales $10,000,000-$50,000,000
# of Employees 120
Plant Area (Sq.Ft.) 128,000
Annual Production 40,000 Pieces
Production Hrs. Annual 2,553
Location (State) WI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $75,480 1,132,864 kWh $0.07
Electricity Demand $43,764 3,855 kW-months/year $11.35
Electricity Fees $16,167 - $ -
Natural Gas $19,776 2,454 MMBtu $8.06
TOTAL ENERGY COSTS $155,187
RECOMMENDED SAVINGS* $28,680 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $3,421
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Solid Waste (non-haz) Electricity Usage Electricity Demand Natural Gas Solid Waste (non-haz)
$ kWh $ kW-months/year $ MMBtu $ lb
01: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,062
Cost:
$660
$1,062 15,945 - - - - - - $1,062
15,945
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
lb
02: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED Savings:
$167
Cost:
$60
$167 2,507 - - - - - - $167
2,507
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
lb
03: 2.7231 USE RADIANT HEATER FOR SPOT HEATING Savings:
$3,162
Cost:
$2,448
- - - - $3,162 529 - - -
-
kWh
-
-
kW-months/year
$3,162
529
MMBtu
-
-
lb
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$259
Cost:
$200
$259 3,885 - - - - - - $259
3,885
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
lb
05: 3.1171 CHANGE PRODUCT SPECS Savings:
$11,780
Cost:
-
- - - - - - $11,780 910 -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$11,780
910
lb
06: 2.7233 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT Savings:
$12,250
Cost:
$19,000
$10,574 158,703 $1,676 148 - - - - $10,574
158,703
kWh
$1,676
148
kW-months/year
-
-
MMBtu
-
-
lb
TOTAL RECOMMENDED Savings:
$28,680
Cost:
$22,368
$12,062 181,040 $1,676 148 $3,162 529 $11,780 910 $12,062
181,040
kWh
$1,676
148
kW-months/year
$3,162
529
MMBtu
$11,780
910
lb
TOTAL IMPLEMENTED Savings:
$3,421
Cost:
$2,648
$259 3,885 - - $3,162 529 - - $259
3,885
kWh
-
-
kW-months/year
$3,162
529
MMBtu
-
-
lb
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ lb