Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 2015
Principal Product Springs, Stampings, Wire Forms
NAICS 332613 - Spring Manufacturing
SIC 3469 - Metal Stampings, Nec
Sales $10,000,000-$50,000,000
# of Employees 80
Plant Area (Sq.Ft.) 67,500
Annual Production 500 Tons
Production Hrs. Annual 5,100
Location (State) IL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $45,992 819,997 kWh $0.06
Electricity Demand $14,446 2,704 kW-months/year $5.34
Electricity Fees $14,114 - $ -
Natural Gas $50,253 4,959 MMBtu $10.13
TOTAL ENERGY COSTS $124,805
RECOMMENDED SAVINGS* $43,665 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $19,363
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.1224 REPLACE BOILER Savings:
$24,302
Cost:
$20,000
- - - - $14,302 1,412 $10,000 - -
-
kWh
-
-
kW-months/year
$14,302
1,412
MMBtu
$10,000
-
$
02: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$7,761
Cost:
$2,291
$7,761 138,342 - - - - - - $7,761
138,342
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
03: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$5,355
Cost:
-
- - - - $5,355 528 - - -
-
kWh
-
-
kW-months/year
$5,355
528
MMBtu
-
-
$
04: 2.1121 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING Savings:
$3,701
Cost:
$1,218
- - - - $3,701 365 - - -
-
kWh
-
-
kW-months/year
$3,701
365
MMBtu
-
-
$
05: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS Savings:
$1,080
Cost:
$110
$882 15,714 $199 37 - - - - $882
15,714
kWh
$199
37
kW-months/year
-
-
MMBtu
-
-
$
06: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$786
Cost:
$3,000
$507 9,043 $279 52 - - - - $507
9,043
kWh
$279
52
kW-months/year
-
-
MMBtu
-
-
$
07: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$680
Cost:
$255
- - - - $680 67 - - -
-
kWh
-
-
kW-months/year
$680
67
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$43,665
Cost:
$26,874
$9,150 163,099 $478 89 $24,038 2,372 $10,000 - $9,150
163,099
kWh
$478
89
kW-months/year
$24,038
2,372
MMBtu
$10,000
-
$
TOTAL IMPLEMENTED Savings:
$19,363
Cost:
$6,874
$9,150 163,099 $478 89 $9,736 960 - - $9,150
163,099
kWh
$478
89
kW-months/year
$9,736
960
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes