IAC logo
IAC Assessment: WM0196
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WM0196
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 2023
Principal Product Testing of Heat Pumps, Water Heaters, Water Treatment
NAICS 339999 - All Other Miscellaneous Manufacturing
SIC 3569 - General Industrial Machinery, Nec
Sales >$500,000,000
# of Employees 65
Plant Area (Sq.Ft.) 47,000
Annual Production 200,000 Pieces
Production Hrs. Annual 3,744
Location (State) WI
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $50,698 844,233 kWh $0.06
Electricity Demand $35,849 2,361 kW-months/year $15.18
Electricity Fees $22,061 - $ -
Natural Gas $48,750 5,623 MMBtu $8.67
TOTAL ENERGY COSTS $157,358
RECOMMENDED SAVINGS* $20,155 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $16,982
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$12,026
Cost:
-
$8,505 141,774 - - $3,521 406 $8,505
141,774
kWh
-
-
kW-months/year
$3,521
406
MMBtu
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$2,584
Cost:
-
- - - - $2,584 298 -
-
kWh
-
-
kW-months/year
$2,584
298
MMBtu
03: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$2,381
Cost:
$1,240
$1,465 24,430 $915 60 - - $1,465
24,430
kWh
$915
60
kW-months/year
-
-
MMBtu
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,020
Cost:
$1,490
$628 10,469 $392 26 - - $628
10,469
kWh
$392
26
kW-months/year
-
-
MMBtu
05: 2.2531 RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR Savings:
$546
Cost:
$213
- - - - $546 63 -
-
kWh
-
-
kW-months/year
$546
63
MMBtu
06: 2.1135 REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY Savings:
$544
Cost:
$240
- - - - $544 63 -
-
kWh
-
-
kW-months/year
$544
63
MMBtu
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$426
Cost:
$1,995
$262 4,371 $164 11 - - $262
4,371
kWh
$164
11
kW-months/year
-
-
MMBtu
08: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$380
Cost:
-
$209 3,491 $170 11 - - $209
3,491
kWh
$170
11
kW-months/year
-
-
MMBtu
09: 2.7133 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE Savings:
$138
Cost:
$125
$138 2,299 - - - - $138
2,299
kWh
-
-
kW-months/year
-
-
MMBtu
10: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT Savings:
$111
Cost:
-
$69 1,146 $43 3 - - $69
1,146
kWh
$43
3
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$20,155
Cost:
$5,303
$11,277 187,979 $1,684 111 $7,195 830 $11,277
187,979
kWh
$1,684
111
kW-months/year
$7,195
830
MMBtu
TOTAL IMPLEMENTED Savings:
$16,982
Cost:
$3,698
$9,605 160,105 $726 48 $6,651 767 $9,605
160,105
kWh
$726
48
kW-months/year
$6,651
767
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas