IAC logo
IAC Assessment: WV0184
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WV0184
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center West Virginia University
Assessment Year 2000
Principal Product Laminated Wood
NAICS n/a
SIC 2421 - Sawmills And Planing Mills, General
Sales $100,000,000-$500,000,000
# of Employees 320
Plant Area (Sq.Ft.) 360,000
Annual Production 5,000 Thousand Feet
Production Hrs. Annual 8,568
Location (State) WV
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,808,501 46,726,847 kWh $0.04
Electricity Demand $693,115 97,762 kW-months/year $7.09
Electricity Fees $39,105 - $ -
Natural Gas $313,911 91,018 MMBtu $3.45
TOTAL ENERGY COSTS $2,854,632
RECOMMENDED SAVINGS* $349,857 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $87,417
#|Description Savings
Cost
Status Electricity Usage Natural Gas Solid Waste (non-haz) Personnel Changes Electricity Usage Natural Gas Solid Waste (non-haz) Personnel Changes
$ kWh $ MMBtu $ lb $ $
01: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$6,707
Cost:
$280
- - $6,707 1,944 - - - - -
-
kWh
$6,707
1,944
MMBtu
-
-
lb
-
-
$
02: 2.7314 REDUCE VENTILATION AIR Savings:
$694
Cost:
$1,170
- - $694 201 - - - - -
-
kWh
$694
201
MMBtu
-
-
lb
-
-
$
03: 2.2426 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR Savings:
$33,886
Cost:
$10,000
- - $33,886 10,075 - - - - -
-
kWh
$33,886
10,075
MMBtu
-
-
lb
-
-
$
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$2,156
Cost:
$220
$2,156 90,270 - - - - - - $2,156
90,270
kWh
-
-
MMBtu
-
-
lb
-
-
$
05: 4.8210 PAY BILLS ON TIME TO AVOID LATE FEES Savings:
$40,958
Cost:
$200
- - $40,958 - - - - - -
-
kWh
$40,958
-
MMBtu
-
-
lb
-
-
$
06: 3.5212 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS Savings:
$4,706
Cost:
$870
- - - - $4,706 - - - -
-
kWh
-
-
MMBtu
$4,706
-
lb
-
-
$
07: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS Savings:
$3,710
Cost:
$11,000
- - - - $3,710 - - - -
-
kWh
-
-
MMBtu
$3,710
-
lb
-
-
$
08: 4.4450 INSTALL EQUIPMENT TO MOVE PRODUCT Savings:
$257,040
Cost:
$105,000
- - - - - - $257,040 - -
-
kWh
-
-
MMBtu
-
-
lb
$257,040
-
$
TOTAL RECOMMENDED Savings:
$349,857
Cost:
$128,740
$2,156 90,270 $82,245 12,220 $8,416 - $257,040 - $2,156
90,270
kWh
$82,245
12,220
MMBtu
$8,416
-
lb
$257,040
-
$
TOTAL IMPLEMENTED Savings:
$87,417
Cost:
$21,700
$2,156 90,270 $81,551 12,019 $3,710 - - - $2,156
90,270
kWh
$81,551
12,019
MMBtu
$3,710
-
lb
-
-
$
Savings
Cost
$ kWh $ MMBtu $ lb $ $
Electricity Usage Natural Gas Solid Waste (non-haz) Personnel Changes Electricity Usage Natural Gas Solid Waste (non-haz) Personnel Changes