IAC logo
IAC Assessment: WV0217
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WV0217
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center West Virginia University
Assessment Year 2001
Principal Product wooden pallets and pallet parts
NAICS n/a
SIC 2421 - Sawmills And Planing Mills, General
Sales $10,000,000-$50,000,000
# of Employees 89
Plant Area (Sq.Ft.) 81,000
Annual Production 12,000 Thousand Feet
Production Hrs. Annual 4,500
Location (State) WV
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $199,587 3,120,018 kWh $0.06
Natural Gas $8,888 1,320 MMBtu $6.73
TOTAL ENERGY COSTS $208,475
RECOMMENDED SAVINGS* $197,431 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $40,870
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$10,319
Cost:
$1,925
$10,319 156,169 - - - - $10,319
156,169
kWh
-
-
MMBtu
-
-
$
02: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$2,187
Cost:
-
- - $2,187 325 - - -
-
kWh
$2,187
325
MMBtu
-
-
$
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,084
Cost:
$54
$1,084 16,408 - - - - $1,084
16,408
kWh
-
-
MMBtu
-
-
$
04: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$1,646
Cost:
$162
$1,646 24,905 - - - - $1,646
24,905
kWh
-
-
MMBtu
-
-
$
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,433
Cost:
$68
$1,433 21,682 - - - - $1,433
21,682
kWh
-
-
MMBtu
-
-
$
06: 2.4157 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM Savings:
$8,151
Cost:
$270
$8,151 125,697 - - - - $8,151
125,697
kWh
-
-
MMBtu
-
-
$
07: 3.6123 BURN WOOD BY-PRODUCTS FOR HEAT Savings:
$136,561
Cost:
$325,000
$136,561 1,565,499 - - - - $136,561
1,565,499
kWh
-
-
MMBtu
-
-
$
08: 4.3230 OPTIMIZE LOT SIZES TO REDUCE INVENTORY CARRYING COSTS Savings:
$16,050
Cost:
$15,248
- - - - $16,050 - -
-
kWh
-
-
MMBtu
$16,050
-
$
09: 4.6520 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES Savings:
$20,000
Cost:
$30,000
- - - - $20,000 - -
-
kWh
-
-
MMBtu
$20,000
-
$
TOTAL RECOMMENDED Savings:
$197,431
Cost:
$372,727
$159,194 1,910,360 $2,187 325 $36,050 - $159,194
1,910,360
kWh
$2,187
325
MMBtu
$36,050
-
$
TOTAL IMPLEMENTED Savings:
$40,870
Cost:
$17,727
$22,633 344,861 $2,187 325 $16,050 - $22,633
344,861
kWh
$2,187
325
MMBtu
$16,050
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes