IAC logo
IAC Assessment: WV0370
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WV0370
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center West Virginia University
Assessment Year 2008
Principal Product printed material
NAICS 323111 - Commercial Printing (except Screen and Books)
SIC 2759 - Commercial Printing, Nec
Sales $100,000,000-$500,000,000
# of Employees 900
Plant Area (Sq.Ft.) 1,600,000
Annual Production 2,147,483,647 Units
Production Hrs. Annual 8,760
Location (State) WV
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $2,482,179 106,798,943 kWh $0.02
Electricity Demand $1,384,046 192,704 kW-months/year $7.18
Natural Gas $5,671,955 573,353 MMBtu $9.89
TOTAL ENERGY COSTS $9,538,180
RECOMMENDED SAVINGS* $1,074,253 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $1,014,768
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Personnel Changes Electricity Usage Electricity Demand Natural Gas Personnel Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.2113 REPAIR OR REPLACE STEAM TRAPS Savings:
$544,142
Cost:
$5,500
- - - - $554,542 56,071 $(-10,400) - -
-
kWh
-
-
kW-months/year
$554,542
56,071
MMBtu
$(-10,400)
-
$
02: 2.2449 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER Savings:
$416,253
Cost:
$371,400
$(-55,180) (-2,378,435) $(-23,393) (-3,264) $494,826 50,033 - - $(-55,180)
(-2,378,435)
kWh
$(-23,393)
(-3,264)
kW-months/year
$494,826
50,033
MMBtu
-
-
$
03: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD Savings:
$44,891
Cost:
$54,835
$37,892 1,633,288 $16,062 2,237 - - $(-9,063) - $37,892
1,633,288
kWh
$16,062
2,237
kW-months/year
-
-
MMBtu
$(-9,063)
-
$
04: 2.4151 DEVELOP A REPAIR/REPLACE POLICY Savings:
$32,574
Cost:
$3,560
$23,045 993,344 $9,769 1,361 - - $(-240) - $23,045
993,344
kWh
$9,769
1,361
kW-months/year
-
-
MMBtu
$(-240)
-
$
05: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$21,799
Cost:
$8,800
$15,309 659,854 $6,490 904 - - - - $15,309
659,854
kWh
$6,490
904
kW-months/year
-
-
MMBtu
-
-
$
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$14,594
Cost:
$2,720
$11,363 489,789 $3,231 450 - - - - $11,363
489,789
kWh
$3,231
450
kW-months/year
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$1,074,253
Cost:
$446,815
$32,429 1,397,840 $12,159 1,688 $1,049,368 106,104 $(-19,703) - $32,429
1,397,840
kWh
$12,159
1,688
kW-months/year
$1,049,368
106,104
MMBtu
$(-19,703)
-
$
TOTAL IMPLEMENTED Savings:
$1,014,768
Cost:
$389,260
$(-16,826) (-725,237) $(-7,134) (-999) $1,049,368 106,104 $(-10,640) - $(-16,826)
(-725,237)
kWh
$(-7,134)
(-999)
kW-months/year
$1,049,368
106,104
MMBtu
$(-10,640)
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Personnel Changes Electricity Usage Electricity Demand Natural Gas Personnel Changes