Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2009 |
Principal Product | Precast Concrete |
NAICS | 238120 - Structural Steel and Precast Concrete Contractors |
SIC | 3272 - Concrete Products, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 180 |
Plant Area (Sq.Ft.) | 189,154 |
Annual Production | 93,400 Units |
Production Hrs. Annual | 5,060 |
Location (State) | VA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $135,840 | 3,256,768 | kWh | $0.04 |
Electricity Demand | $69,805 | 8,854 | kW-months/year | $7.88 |
Electricity Fees | $567 | - | $ | - |
Natural Gas | $353,514 | 26,363 | MMBtu | $13.41 |
TOTAL ENERGY COSTS | $559,726 | |||
RECOMMENDED SAVINGS* | $79,257 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $21,637 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $27,893 Cost: $26,000 |
- | - | - | - | $27,893 | 2,080 | - | - |
- - kWh |
- - kW-months/year |
$27,893 2,080 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $11,811 Cost: $6,850 |
$8,155 | 195,518 | $3,656 | 464 | - | - | - | - |
$8,155 195,518 kWh |
$3,656 464 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $11,520 Cost: $800 |
- | - | - | - | $11,573 | 863 | $(-53) | - |
- - kWh |
- - kW-months/year |
$11,573 863 MMBtu |
$(-53) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $9,238 Cost: $8,890 |
$6,378 | 152,901 | $2,860 | 363 | - | - | - | - |
$6,378 152,901 kWh |
$2,860 363 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $4,896 Cost: $8,900 |
$3,383 | 81,114 | $1,513 | 192 | - | - | - | - |
$3,383 81,114 kWh |
$1,513 192 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $4,483 Cost: $105 |
$3,096 | 74,226 | $1,387 | 176 | - | - | - | - |
$3,096 74,226 kWh |
$1,387 176 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $3,782 Cost: $8,543 |
- | - | - | - | $3,782 | 282 | - | - |
- - kWh |
- - kW-months/year |
$3,782 282 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $2,651 Cost: $605 |
$1,978 | 47,412 | $883 | 112 | - | - | $(-210) | - |
$1,978 47,412 kWh |
$883 112 kW-months/year |
- - MMBtu |
$(-210) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4157 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM |
Savings: $2,609 Cost: $1,000 |
$1,898 | 45,516 | $851 | 108 | - | - | $(-140) | - |
$1,898 45,516 kWh |
$851 108 kW-months/year |
- - MMBtu |
$(-140) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $374 Cost: $300 |
$215 | 5,154 | $159 | 12 | - | - | - | - |
$215 5,154 kWh |
$159 12 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $79,257 Cost: $61,993 |
$25,103 | 601,841 | $11,309 | 1,427 | $43,248 | 3,225 | $(-403) | - | $25,103 601,841 kWh |
$11,309 1,427 kW-months/year |
$43,248 3,225 MMBtu |
$(-403) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $21,637 Cost: $2,810 |
$7,187 | 172,308 | $3,280 | 408 | $11,573 | 863 | $(-403) | - | $7,187 172,308 kWh |
$3,280 408 kW-months/year |
$11,573 863 MMBtu |
$(-403) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |