Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2011 |
Principal Product | Lamp Products |
NAICS | 335121 - Residential Electric Lighting Fixture Manufacturing |
SIC | 3645 - Residential Lighting Fixtures |
Sales | $100,000,000-$500,000,000 |
# of Employees | 401 |
Plant Area (Sq.Ft.) | 520,000 |
Annual Production | 500,000,000 Pieces |
Production Hrs. Annual | 8,400 |
Location (State) | PA |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $647,790 | 27,470,798 | kWh | $0.02 |
Electricity Demand | $407,019 | 47,713 | kW-months/year | $8.53 |
Natural Gas | $1,714,379 | 171,617 | MMBtu | $9.99 |
TOTAL ENERGY COSTS | $2,769,188 | |||
RECOMMENDED SAVINGS* | $539,867 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $15,589 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $358,430 Cost: $44,500 |
$(-690) | (-28,980) | $(-350) | (-41) | $359,470 | 35,983 | - | - |
$(-690) (-28,980) kWh |
$(-350) (-41) kW-months/year |
$359,470 35,983 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2427 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT INCOMING FLUIDS |
Savings: $128,784 Cost: $122,980 |
$(-3,046) | (-127,939) | $(-1,561) | (-183) | $138,391 | 13,853 | $(-5,000) | - |
$(-3,046) (-127,939) kWh |
$(-1,561) (-183) kW-months/year |
$138,391 13,853 MMBtu |
$(-5,000) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $29,992 Cost: $32,300 |
$21,568 | 906,225 | $8,424 | 988 | - | - | - | - |
$21,568 906,225 kWh |
$8,424 988 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $9,251 Cost: $9,400 |
- | - | - | - | $9,251 | 926 | - | - |
- - kWh |
- - kW-months/year |
$9,251 926 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7131 ADD AREA LIGHTING SWITCHES |
Savings: $5,883 Cost: $20,000 |
$3,947 | 165,822 | $1,936 | 227 | - | - | - | - |
$3,947 165,822 kWh |
$1,936 227 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $4,760 Cost: - |
$3,148 | 132,143 | $1,612 | 189 | - | - | - | - |
$3,148 132,143 kWh |
$1,612 189 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $1,578 Cost: $3,004 |
- | - | - | - | $1,578 | 158 | - | - |
- - kWh |
- - kW-months/year |
$1,578 158 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $1,189 Cost: $4,200 |
- | - | - | - | $1,189 | 119 | - | - |
- - kWh |
- - kW-months/year |
$1,189 119 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $539,867 Cost: $236,384 |
$24,927 | 1,047,271 | $10,061 | 1,180 | $509,879 | 51,039 | $(-5,000) | - | $24,927 1,047,271 kWh |
$10,061 1,180 kW-months/year |
$509,879 51,039 MMBtu |
$(-5,000) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $15,589 Cost: $12,404 |
$3,148 | 132,143 | $1,612 | 189 | $10,829 | 1,084 | - | - | $3,148 132,143 kWh |
$1,612 189 kW-months/year |
$10,829 1,084 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |