Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2019 |
Principal Product | Waste Water Treatment |
NAICS | 221320 - Sewage Treatment Facilities |
SIC | 4952 - Sewerage Systems |
Sales | $10,000,000-$50,000,000 |
# of Employees | 9 |
Plant Area (Sq.Ft.) | 460,000 |
Annual Production | 2,060,000 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $343,479 | 3,585,000 | kWh | $0.10 |
Electricity Demand | $58,968 | 7,560 | kW-months/year | $7.80 |
Natural Gas | $7,446 | 967 | MMBtu | $7.70 |
TOTAL ENERGY COSTS | $409,893 | |||
RECOMMENDED SAVINGS* | $39,515 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $21,006 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4157 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM |
Savings: $12,987 Cost: $1,000 |
$13,836 | 144,426 | - | - | - | - | $(-849) | - |
$13,836 144,426 kWh |
- - kW-months/year |
- - $ |
$(-849) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $6,442 Cost: $38,062 |
$6,442 | 67,247 | - | - | - | - | - | - |
$6,442 67,247 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4313 PROVIDE PROPER MAINTENANCE OF MOTOR DRIVEN EQUIPMENT |
Savings: $6,835 Cost: $6,336 |
$6,149 | 64,188 | $686 | 88 | - | - | - | - |
$6,149 64,188 kWh |
$686 88 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $5,205 Cost: $2,889 |
$4,573 | 47,733 | $632 | 81 | - | - | - | - |
$4,573 47,733 kWh |
$632 81 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $2,814 Cost: $587 |
$2,724 | 28,435 | $304 | 39 | - | - | $(-214) | - |
$2,724 28,435 kWh |
$304 39 kW-months/year |
- - $ |
$(-214) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $5,232 Cost: $5,400 |
- | - | - | - | $5,232 | - | - | - |
- - kWh |
- - kW-months/year |
$5,232 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $39,515 Cost: $54,274 |
$33,724 | 352,029 | $1,622 | 208 | $5,232 | - | $(-1,063) | - | $33,724 352,029 kWh |
$1,622 208 kW-months/year |
$5,232 - $ |
$(-1,063) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $21,006 Cost: $4,476 |
$21,133 | 220,594 | $936 | 120 | - | - | $(-1,063) | - | $21,133 220,594 kWh |
$936 120 kW-months/year |
- - $ |
$(-1,063) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes |