Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2020 |
Principal Product | processed meat |
NAICS | 311612 - Meat Processed from Carcasses |
SIC | 2011 - Meat Packing Plants |
Sales | $10,000,000-$50,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 78,000 |
Annual Production | 25,000 Pounds |
Production Hrs. Annual | 8,736 |
Location (State) | WV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $69,522 | 1,986,540 | kWh | $0.03 |
Electricity Demand | $79,373 | 4,395 | kW-months/year | $18.06 |
Electricity Fees | $4,735 | - | $ | - |
Natural Gas | $9,977 | 1,292 | MMBtu | $7.72 |
TOTAL ENERGY COSTS | $165,271 | |||
RECOMMENDED SAVINGS* | $77,893 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $10,239 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Usage | Water Disposal | Personnel Changes | Primary Product | Electricity Usage | Electricity Demand | Water Usage | Water Disposal | Personnel Changes | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | Tgal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.126 INSTALL SENSORS TO DETECT DEFECTS |
Savings: $30,600 Cost: $10,470 |
- | - | - | - | - | - | - | - | - | - | $30,600 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
$30,600 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL |
Savings: $28,134 Cost: $48,344 |
$16,467 | 470,494 | $11,667 | 646 | - | - | - | - | - | - | - | - |
$16,467 470,494 kWh |
$11,667 646 kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4145 INSTALL ISOLATION TRANSFORMER ON ADJUSTABLE FREQUENCY DRIVE |
Savings: $8,920 Cost: $11,220 |
$4,586 | 131,040 | $4,334 | 240 | - | - | - | - | - | - | - | - |
$4,586 131,040 kWh |
$4,334 240 kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $7,292 Cost: $6,768 |
$2,506 | 71,598 | $4,786 | 265 | - | - | - | - | - | - | - | - |
$2,506 71,598 kWh |
$4,786 265 kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5131 RECYCLE WHITE WATER |
Savings: $1,467 Cost: $3,170 |
$(-23) | (-671) | - | - | $691 | 117 | $799 | 117 | - | - | - | - |
$(-23) (-671) kWh |
- - kW-months/year |
$691 117 Tgal |
$799 117 Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $916 Cost: $1,021 |
$1,696 | 48,466 | $(-780) | (-43) | - | - | - | - | - | - | - | - |
$1,696 48,466 kWh |
$(-780) (-43) kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $564 Cost: $613 |
$427 | 12,189 | $307 | 17 | - | - | - | - | $(-170) | - | - | - |
$427 12,189 kWh |
$307 17 kW-months/year |
- - Tgal |
- - Tgal |
$(-170) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $77,893 Cost: $81,606 |
$25,659 | 733,116 | $20,314 | 1,125 | $691 | 117 | $799 | 117 | $(-170) | - | $30,600 | - | $25,659 733,116 kWh |
$20,314 1,125 kW-months/year |
$691 117 Tgal |
$799 117 Tgal |
$(-170) - $ |
$30,600 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $10,239 Cost: $11,572 |
$4,606 | 131,582 | $4,313 | 239 | $691 | 117 | $799 | 117 | $(-170) | - | - | - | $4,606 131,582 kWh |
$4,313 239 kW-months/year |
$691 117 Tgal |
$799 117 Tgal |
$(-170) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | Tgal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Usage | Water Disposal | Personnel Changes | Primary Product | Electricity Usage | Electricity Demand | Water Usage | Water Disposal | Personnel Changes | Primary Product |