IAC logo
IAC Assessment: WV0644
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WV0644
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center West Virginia University
Assessment Year 2023
Principal Product Custom Cabinetry
NAICS 337110 - Wood Kitchen Cabinet and Countertop Manufacturing
SIC 2434 - Wood Kitchen Cabinets
Sales $10,000,000-$50,000,000
# of Employees 80
Plant Area (Sq.Ft.) 970,000
Annual Production 5,100 Pieces
Production Hrs. Annual 4,590
Location (State) WV
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $42,475 834,390 kWh $0.05
Electricity Demand $42,141 2,857 kW-months/year $14.75
Electricity Fees $3,640 - $ -
LPG $54,405 2,647 MMBtu $20.55
TOTAL ENERGY COSTS $143,638
RECOMMENDED SAVINGS* $41,030 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $7,373
#|Description Savings
Cost
Status Electricity Usage Electricity Demand LPG Personnel Changes Electricity Usage Electricity Demand LPG Personnel Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$23,558
Cost:
$12,360
$13,779 254,701 $9,779 663 - - - - $13,779
254,701
kWh
$9,779
663
kW-months/year
-
-
MMBtu
-
-
$
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$6,092
Cost:
$29,560
$556 10,272 $398 27 $5,138 250 - - $556
10,272
kWh
$398
27
kW-months/year
$5,138
250
MMBtu
-
-
$
03: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$4,500
Cost:
$1,023
- - - - $4,500 219 - - -
-
kWh
-
-
kW-months/year
$4,500
219
MMBtu
-
-
$
04: 2.2449 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER Savings:
$4,007
Cost:
$10,420
- - - - $4,007 195 - - -
-
kWh
-
-
kW-months/year
$4,007
195
MMBtu
-
-
$
05: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$954
Cost:
$1,965
$836 15,462 $118 8 - - - - $836
15,462
kWh
$118
8
kW-months/year
-
-
MMBtu
-
-
$
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$530
Cost:
$100
$309 5,707 $221 15 - - - - $309
5,707
kWh
$221
15
kW-months/year
-
-
MMBtu
-
-
$
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$523
Cost:
$1,573
$269 4,964 $192 13 $62 3 - - $269
4,964
kWh
$192
13
kW-months/year
$62
3
MMBtu
-
-
$
08: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$459
Cost:
$1,293
$263 4,864 $196 13 - - - - $263
4,864
kWh
$196
13
kW-months/year
-
-
MMBtu
-
-
$
09: 2.4151 DEVELOP A REPAIR/REPLACE POLICY Savings:
$310
Cost:
$592
$200 3,695 $148 10 - - $(-38) - $200
3,695
kWh
$148
10
kW-months/year
-
-
MMBtu
$(-38)
-
$
10: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$76
Cost:
$368
$46 841 $30 2 - - - - $46
841
kWh
$30
2
kW-months/year
-
-
MMBtu
-
-
$
11: 2.2511 INSULATE BARE EQUIPMENT Savings:
$21
Cost:
$31
- - - - $21 1 - - -
-
kWh
-
-
kW-months/year
$21
1
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$41,030
Cost:
$59,285
$16,258 300,506 $11,082 751 $13,728 668 $(-38) - $16,258
300,506
kWh
$11,082
751
kW-months/year
$13,728
668
MMBtu
$(-38)
-
$
TOTAL IMPLEMENTED Savings:
$7,373
Cost:
$6,945
$1,923 35,533 $905 61 $4,583 223 $(-38) - $1,923
35,533
kWh
$905
61
kW-months/year
$4,583
223
MMBtu
$(-38)
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand LPG Personnel Changes Electricity Usage Electricity Demand LPG Personnel Changes