Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | West Virginia University |
---|---|
Assessment Year | 2025 |
Principal Product | Wax, Laundry detergent, Hand soap, Bleach, Sanitizers |
NAICS | 325611 - Soap and Other Detergent Manufacturing |
SIC | 2841 - Soap And Other Detergents |
Sales | $10,000,000-$50,000,000 |
# of Employees | 159 |
Plant Area (Sq.Ft.) | 228,000 |
Annual Production | 292,327,620 Pounds |
Production Hrs. Annual | 6,240 |
Location (State) | WV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $274,655 | 3,612,777 | kWh | $0.08 |
Electricity Demand | $79,621 | 7,547 | kW-months/year | $10.55 |
Electricity Fees | $7,820 | - | $ | - |
Natural Gas | $366,194 | 70,154 | MMBtu | $5.22 |
TOTAL ENERGY COSTS | $728,290 | |||
RECOMMENDED SAVINGS* | $95,544 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7314 REDUCE VENTILATION AIR |
Savings: $61,627 Cost: $6,564 |
- | - | - | - | $61,627 | 11,806 | - | - |
- - kWh |
- - kW-months/year |
$61,627 11,806 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $6,659 Cost: $13,993 |
$3,832 | 50,418 | $2,827 | 268 | - | - | - | - |
$3,832 50,418 kWh |
$2,827 268 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $6,537 Cost: $11,140 |
$4,775 | 62,824 | $1,762 | 167 | - | - | - | - |
$4,775 62,824 kWh |
$1,762 167 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $6,161 Cost: $28,584 |
$5,433 | 71,492 | $728 | 69 | - | - | - | - |
$5,433 71,492 kWh |
$728 69 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,095 Cost: $308 |
$2,441 | 32,120 | $654 | 62 | - | - | - | - |
$2,441 32,120 kWh |
$654 62 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2449 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER |
Savings: $2,997 Cost: $12,500 |
$(-840) | (-11,056) | - | - | $3,837 | 735 | - | - |
$(-840) (-11,056) kWh |
- - kW-months/year |
$3,837 735 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $2,735 Cost: $1,187 |
- | - | - | - | $2,735 | 524 | - | - |
- - kWh |
- - kW-months/year |
$2,735 524 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2113 REPAIR OR REPLACE STEAM TRAPS |
Savings: $1,772 Cost: $8,336 |
- | - | - | - | $1,921 | 368 | $(-149) | - |
- - kWh |
- - kW-months/year |
$1,921 368 MMBtu |
$(-149) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,747 Cost: $8,115 |
$1,258 | 16,559 | $338 | 32 | $151 | 29 | - | - |
$1,258 16,559 kWh |
$338 32 kW-months/year |
$151 29 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,342 Cost: $3,197 |
$909 | 11,962 | $433 | 41 | - | - | - | - |
$909 11,962 kWh |
$433 41 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $648 Cost: $782 |
$511 | 6,719 | $137 | 13 | - | - | - | - |
$511 6,719 kWh |
$137 13 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $224 Cost: $391 |
- | - | - | - | $224 | 43 | - | - |
- - kWh |
- - kW-months/year |
$224 43 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $95,544 Cost: $95,097 |
$18,319 | 241,038 | $6,879 | 652 | $70,495 | 13,505 | $(-149) | - | $18,319 241,038 kWh |
$6,879 652 kW-months/year |
$70,495 13,505 MMBtu |
$(-149) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |