Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,566
matching recommendationsNAICS | 3114 | Fruit and Vegetable Preserving and Specialty Food Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0321 # 06 Y:2006 | 06 | 2006 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,410 | $2,345 | Not Implemented |
SF0321 # 07 Y:2006 | 07 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $554 | $780 | Implemented |
SF0321 # 08 Y:2006 | 08 | 2006 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $10,550 | $25,410 | Implemented |
SF0321 # 09 Y:2006 | 09 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,170 | $11,928 | Implemented |
SF0319 # 01 Y:2006 | 01 | 2006 | USE PHOTOCELL CONTROLS | $381 | $360 | Not Implemented |
SF0319 # 02 Y:2006 | 02 | 2006 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $19,568 | $19,053 | Not Implemented |
SF0319 # 03 Y:2006 | 03 | 2006 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $18,204 | $20,250 | Implemented |
SF0319 # 04 Y:2006 | 04 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $18,411 | $23,058 | Implemented |
SF0319 # 05 Y:2006 | 05 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,934 | $18,325 | Implemented |
SF0319 # 06 Y:2006 | 06 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,552 | $4,648 | Implemented |
LM0108 # 01 Y:2006 | 01 | 2006 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $42,160 | $64,000 | Not Implemented |
LM0108 # 02 Y:2006 | 02 | 2006 | UPGRADE CONTROLS ON COMPRESSORS | $9,822 | $0 | Not Implemented |
LM0108 # 03 Y:2006 | 03 | 2006 | CROSS-TRAIN PERSONNEL TO AVOID LOST TIME | $287,197 | $0 | Implemented |
LM0108 # 04 Y:2006 | 04 | 2006 | SCHEDULE DELIVERIES ACCORDING TO DEMAND | $16,460 | $0 | Implemented |
LM0108 # 05 Y:2006 | 05 | 2006 | CROSS-TRAIN PERSONNEL TO AVOID LOST TIME | $184,119 | $15,120 | Implemented |
IC0110 # 01 Y:2005 | 01 | 2005 | REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE | $106,617 | $213,420 | Implemented |
IC0110 # 02 Y:2005 | 02 | 2005 | SUBSTITUTE HOT PROCESS FLUIDS FOR STEAM | $79,621 | $634,572 | Not Implemented |
IC0110 # 03 Y:2005 | 03 | 2005 | REPAIR OR REPLACE STEAM TRAPS | $29,831 | $1,638 | Implemented |
IC0110 # 04 Y:2005 | 04 | 2005 | REPAIR AND ELIMINATE STEAM LEAKS | $6,051 | $400 | Implemented |
IC0110 # 05 Y:2005 | 05 | 2005 | IMPROVE COMBUSTION CONTROL CAPABILITY | $13,789 | $3,500 | Implemented |
IC0110 # 06 Y:2005 | 06 | 2005 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,956 | $0 | Implemented |
IC0110 # 07 Y:2005 | 07 | 2005 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $7,443 | $15,000 | Not Implemented |
IC0110 # 08 Y:2005 | 08 | 2005 | OPTIMIZE PLANT POWER FACTOR | $13,904 | $70,000 | Implemented |
IC0110 # 09 Y:2005 | 09 | 2005 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $17,156 | $81,881 | Implemented |
IC0110 # 10 Y:2005 | 10 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $473 | $3,388 | Implemented |