Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
88
matching recommendationsNAICS | 3118 | Bakeries and Tortilla Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0910 # 01 Y:2018 | 01 | 2018 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $394 | $189 | Not Implemented |
GT0910 # 04 Y:2018 | 04 | 2018 | USE SOLAR HEAT TO MAKE ELECTRICTY | $82,347 | $959,000 | Not Implemented |
GT0910 # 03 Y:2018 | 03 | 2018 | INSULATE BARE EQUIPMENT | $541 | $1,237 | Implemented |
GT0910 # 02 Y:2018 | 02 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,351 | $14,618 | Implemented |
GT0904 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,146 | $24,031 | Not Implemented |
GT0904 # 03 Y:2017 | 03 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $32,294 | $28,344 | Not Implemented |
GT0904 # 02 Y:2017 | 02 | 2017 | TURN OFF EQUIPMENT WHEN NOT IN USE | $5,595 | $2,500 | Not Implemented |
GT0904 # 01 Y:2017 | 01 | 2017 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $8,315 | $100 | Implemented |
UA0145 # 06 Y:2015 | 06 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $14,679 | $2,995 | Implemented |
UA0145 # 02 Y:2015 | 02 | 2015 | INSTALL OCCUPANCY SENSORS | $525 | $822 | Implemented |
UA0145 # 05 Y:2015 | 05 | 2015 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $15,077 | $800 | Not Implemented |
UA0145 # 07 Y:2015 | 07 | 2015 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,579 | $1,800 | Not Implemented |
UA0145 # 04 Y:2015 | 04 | 2015 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $20,453 | $39,438 | Not Implemented |
UA0145 # 03 Y:2015 | 03 | 2015 | USE PHOTOCELL CONTROLS | $328 | $61 | Implemented |
UA0145 # 08 Y:2015 | 08 | 2015 | INSTALL TIMERS AND/OR THERMOSTATS | $3,588 | $80 | Not Implemented |
UA0145 # 09 Y:2015 | 09 | 2015 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $99,699 | $100 | Not Implemented |
UA0145 # 01 Y:2015 | 01 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $94,692 | $86,201 | Not Implemented |
GT0861 # 05 Y:2009 | 05 | 2009 | INSULATE BARE EQUIPMENT | $98,000 | $244,260 | Implemented |
GT0861 # 06 Y:2009 | 06 | 2009 | INSULATE BARE EQUIPMENT | $6,025 | $951 | Implemented |
GT0861 # 07 Y:2009 | 07 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,257 | $2,400 | Not Implemented |
GT0861 # 08 Y:2009 | 08 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,345 | $17,129 | Not Implemented |
GT0861 # 09 Y:2009 | 09 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,933 | $60,324 | Not Implemented |
GT0861 # 10 Y:2009 | 10 | 2009 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $83,157 | $231,450 | Not Implemented |
GT0861 # 04 Y:2009 | 04 | 2009 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $4,626 | $0 | Not Implemented |
GT0861 # 03 Y:2009 | 03 | 2009 | ADJUST BURNERS FOR EFFICIENT OPERATION | $38,729 | $40,000 | Implemented |