Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
193
matching recommendationsNAICS | 3121 | Beverage Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0316 # 11 Y:2017 | 11 | 2017 | INSTALL OCCUPANCY SENSORS | $4,454 | $1,280 | Implemented |
MI0316 # 12 Y:2017 | 12 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,829 | $4,674 | Implemented |
MI0316 # 13 Y:2017 | 13 | 2017 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,011 | $654 | Implemented |
MI0316 # 09 Y:2017 | 09 | 2017 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,991 | $2,140 | Implemented |
MI0316 # 08 Y:2017 | 08 | 2017 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $8,115 | $18,100 | Not Implemented |
MI0316 # 07 Y:2017 | 07 | 2017 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $9,887 | $4,577 | Not Implemented |
MI0316 # 06 Y:2017 | 06 | 2017 | INSTALL OCCUPANCY SENSORS | $10,816 | $7,881 | Implemented |
MI0316 # 05 Y:2017 | 05 | 2017 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $14,995 | $120 | Implemented |
MI0316 # 04 Y:2017 | 04 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,732 | $1,660 | Implemented |
MI0316 # 03 Y:2017 | 03 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $24,854 | $61,030 | Implemented |
MI0316 # 02 Y:2017 | 02 | 2017 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $72,034 | $39,216 | Implemented |
MI0316 # 01 Y:2017 | 01 | 2017 | USE EXCESS COLD PROCESS FLUID FOR INDUSTRIAL COOLING NEEDS | $313,428 | $142,400 | Not Implemented |
MI0316 # 10 Y:2017 | 10 | 2017 | USE PHOTOCELL CONTROLS | $4,891 | $4,136 | Not Implemented |
MI0279 # 11 Y:2015 | 11 | 2015 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,317 | $3,280 | Not Implemented |
MI0279 # 01 Y:2015 | 01 | 2015 | INCREASE EFFICIENCY OF TRUCKS | $30,426 | $29,000 | Not Implemented |
MI0279 # 02 Y:2015 | 02 | 2015 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $29,100 | $80,000 | Not Implemented |
MI0279 # 03 Y:2015 | 03 | 2015 | RECOVER AND REUSE COOLING WATER | $12,134 | $497 | Implemented |
MI0279 # 04 Y:2015 | 04 | 2015 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $11,413 | $12,060 | Implemented |
MI0279 # 06 Y:2015 | 06 | 2015 | USE OPTIMUM THICKNESS INSULATION | $4,666 | $1,810 | Implemented |
MI0279 # 13 Y:2015 | 13 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $634 | $1,760 | Implemented |
MI0279 # 12 Y:2015 | 12 | 2015 | USE PHOTOCELL CONTROLS | $1,139 | $480 | Implemented |
MI0279 # 10 Y:2015 | 10 | 2015 | INSTALL OCCUPANCY SENSORS | $1,456 | $1,782 | Not Implemented |
MI0279 # 08 Y:2015 | 08 | 2015 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,877 | $2,520 | Implemented |
MI0279 # 05 Y:2015 | 05 | 2015 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $10,141 | $2,100 | Implemented |
MI0279 # 07 Y:2015 | 07 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $4,329 | $40 | Implemented |