Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
193
matching recommendationsNAICS | 3121 | Beverage Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0279 # 13 Y:2015 | 13 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $634 | $1,760 | Implemented |
UF0446 # 01 Y:2011 | 01 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,055 | $43,715 | Not Implemented |
UF0446 # 02 Y:2011 | 02 | 2011 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $6,009 | $1,320 | Not Implemented |
UF0446 # 03 Y:2011 | 03 | 2011 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $11,224 | $3,045 | Not Implemented |
UF0446 # 04 Y:2011 | 04 | 2011 | INSTALL OCCUPANCY SENSORS | $3,392 | $396 | Not Implemented |
UF0446 # 05 Y:2011 | 05 | 2011 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $2,063 | $0 | Not Implemented |
UF0446 # 06 Y:2011 | 06 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $86,813 | $350,000 | Not Implemented |
UF0446 # 07 Y:2011 | 07 | 2011 | COVER OPEN TANKS | $2,910 | $1,175 | Not Implemented |
UF0446 # 08 Y:2011 | 08 | 2011 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $9,593 | $25,700 | Not Implemented |
UF0446 # 09 Y:2011 | 09 | 2011 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $1,662 | $8,210 | Not Implemented |
UF0440 # 01 Y:2011 | 01 | 2011 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $43,145 | $25,340 | Not Implemented |
UF0440 # 02 Y:2011 | 02 | 2011 | CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD | $3,404 | $5,896 | Not Implemented |
UF0440 # 03 Y:2011 | 03 | 2011 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $1,173 | $1,818 | Not Implemented |
UF0440 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,370 | $3,778 | Not Implemented |
UF0440 # 05 Y:2011 | 05 | 2011 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $28,580 | $12,180 | Not Implemented |
UF0440 # 06 Y:2011 | 06 | 2011 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $136 | $244 | Not Implemented |
UF0440 # 07 Y:2011 | 07 | 2011 | INSTALL TURBULATORS | $3,745 | $3,750 | Not Implemented |
UF0440 # 08 Y:2011 | 08 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,493 | $9,387 | Not Implemented |
UF0440 # 09 Y:2011 | 09 | 2011 | INSTALL OCCUPANCY SENSORS | $2,620 | $243 | Not Implemented |
UF0440 # 10 Y:2011 | 10 | 2011 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $635 | $0 | Not Implemented |
UF0440 # 11 Y:2011 | 11 | 2011 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $1,423 | $840 | Not Implemented |
MI0191 # 01 Y:2010 | 01 | 2010 | HEAT WATER WITH EXHAUST HEAT | $697,331 | $128,000 | Not Implemented |
MI0191 # 02 Y:2010 | 02 | 2010 | USE EXCESS COLD PROCESS FLUID FOR INDUSTRIAL COOLING NEEDS | $228,145 | $400,000 | Not Implemented |
MI0191 # 03 Y:2010 | 03 | 2010 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $48,196 | $1,500 | Not Implemented |
MI0191 # 04 Y:2010 | 04 | 2010 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $47,683 | $1,210 | Implemented |