IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

21

matching recommendations
Reset
NAICS 321911 Wood Window and Door Manufacturing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OR0574 # 07 Y:2011 07 2011 ADOPT IN-HOUSE MATERIAL GENERATION $228,949 $487,000 Not Implemented
OR0574 # 06 Y:2011 06 2011 FLASH CONDENSATE TO PRODUCE LOWER PRESSURE STEAM $8,495 $18,038 Not Implemented
OR0574 # 05 Y:2011 05 2011 REDUCE FLUID FLOW RATES $4,812 $18,000 Not Implemented
OR0574 # 04 Y:2011 04 2011 REDUCE FLUID FLOW RATES $13,265 $25,000 Not Implemented
OR0574 # 03 Y:2011 03 2011 REDUCE FLUID FLOW RATES $9,209 $15,000 Not Implemented
OR0574 # 02 Y:2011 02 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,450 $7,166 Implemented
OR0574 # 01 Y:2011 01 2011 INSTALL OCCUPANCY SENSORS $35,460 $21,200 Not Implemented
MS0380 # 03 Y:2011 03 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $81,959 $85,986 Not Implemented
MS0380 # 06 Y:2011 06 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,944 $466 Not Implemented
MS0380 # 05 Y:2011 05 2011 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $30,363 $7,080 Not Implemented
MS0380 # 04 Y:2011 04 2011 RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT $8,239 $4,272 Not Implemented
MS0380 # 02 Y:2011 02 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $123,143 $194,049 Not Implemented
MS0380 # 01 Y:2011 01 2011 REPAIR AND ELIMINATE STEAM LEAKS $19,820 $561 Not Implemented
LE0314 # 01 Y:2011 01 2011 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $25,497 $12,000 Not Implemented
LE0314 # 08 Y:2011 08 2011 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $16,017 $39,066 Not Implemented
LE0314 # 07 Y:2011 07 2011 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $3,127 $7,000 Not Implemented
LE0314 # 06 Y:2011 06 2011 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $1,532 $0 Implemented
LE0314 # 05 Y:2011 05 2011 INSULATE BARE EQUIPMENT $4,063 $8,007 Not Implemented
LE0314 # 04 Y:2011 04 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,832 $1,420 Implemented
LE0314 # 03 Y:2011 03 2011 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $10,295 $15,000 Not Implemented
LE0314 # 02 Y:2011 02 2011 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $11,409 $580 Implemented