Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
18
matching recommendationsNAICS | 32221 | Paperboard Container Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0810 # 05 Y:2011 | 05 | 2011 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $2,915 | $0 | Not Implemented |
OK0810 # 04 Y:2011 | 04 | 2011 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $5,317 | $0 | Implemented |
OK0810 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,360 | $14,062 | Not Implemented |
OK0810 # 02 Y:2011 | 02 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $44,840 | $11,400 | Implemented |
OK0810 # 01 Y:2011 | 01 | 2011 | USE DIRECT FLAME IMPINGEMENT OR INFRARED PROCESSING FOR CHAMBER TYPE HEATING | $41,808 | $12,400 | Not Implemented |
OK0808 # 03 Y:2011 | 03 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,547 | $17,879 | Implemented |
OK0808 # 06 Y:2011 | 06 | 2011 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $27,934 | $5,125 | Implemented |
OK0808 # 05 Y:2011 | 05 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $23,465 | $16,400 | Not Implemented |
OK0808 # 04 Y:2011 | 04 | 2011 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,907 | $5,105 | Implemented |
OK0808 # 02 Y:2011 | 02 | 2011 | USE POWER DURING OFF-PEAK PERIODS | $19,801 | $226 | Implemented |
OK0808 # 01 Y:2011 | 01 | 2011 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $11,989 | $1,776 | Not Implemented |
MS0222 # 01 Y:2003 | 01 | 2003 | PREHEAT COMBUSTION AIR WITH WASTE HEAT | $11,730 | $8,788 | Not Implemented |
MS0222 # 07 Y:2003 | 07 | 2003 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $1,680 | $400 | Not Implemented |
MS0222 # 06 Y:2003 | 06 | 2003 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,717 | $1,717 | Not Implemented |
MS0222 # 05 Y:2003 | 05 | 2003 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,994 | $0 | Not Implemented |
MS0222 # 04 Y:2003 | 04 | 2003 | USE RADIANT HEATER FOR SPOT HEATING | $2,158 | $1,649 | Not Implemented |
MS0222 # 03 Y:2003 | 03 | 2003 | REPAIR AND ELIMINATE STEAM LEAKS | $2,178 | $90 | Implemented |
MS0222 # 02 Y:2003 | 02 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,928 | $196 | Implemented |