Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
32
matching recommendationsNAICS | 32311 | Printing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CM1008 # 02 Y:2022 | 02 | 2022 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $23,000 | $43,000 | Not Implemented |
CM1008 # 03 Y:2022 | 03 | 2022 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $81,100 | $8,000 | Not Implemented |
CM1008 # 04 Y:2022 | 04 | 2022 | INCREASE EFFICIENCY OF TRUCKS | $25,700 | $77,000 | Not Implemented |
CM1008 # 05 Y:2022 | 05 | 2022 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $4,470 | $0 | Not Implemented |
CM1008 # 01 Y:2022 | 01 | 2022 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,300 | $440 | Not Implemented |
CO0740 # 04 Y:2021 | 04 | 2021 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,332 | $0 | Not Implemented |
CO0740 # 02 Y:2021 | 02 | 2021 | USE SOLAR HEAT TO MAKE ELECTRICTY | $28,176 | $298,655 | Not Implemented |
CO0740 # 03 Y:2021 | 03 | 2021 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $372 | $617 | Not Implemented |
CO0740 # 01 Y:2021 | 01 | 2021 | RECOVER WASTE HEAT FROM EQUIPMENT | $14,076 | $28,500 | Not Implemented |
CO0740 # 05 Y:2021 | 05 | 2021 | INSTALL OCCUPANCY SENSORS | $6,421 | $667 | Implemented |
CO0632 # 04 Y:2010 | 04 | 2010 | USE SOLAR HEAT TO MAKE ELECTRICTY | $1,760 | $10,500 | Not Implemented |
CO0632 # 03 Y:2010 | 03 | 2010 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,870 | $1,220 | Not Implemented |
CO0632 # 02 Y:2010 | 02 | 2010 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $6,290 | $21,810 | Not Implemented |
CO0632 # 01 Y:2010 | 01 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,960 | $18,470 | Implemented |
CO0632 # 05 Y:2010 | 05 | 2010 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $530 | $2,030 | Not Implemented |
CO0625 # 01 Y:2009 | 01 | 2009 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,200 | $1,500 | Not Implemented |
CO0625 # 02 Y:2009 | 02 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,150 | $17,870 | Not Implemented |
CO0625 # 03 Y:2009 | 03 | 2009 | USE SOLAR HEAT TO MAKE ELECTRICTY | $1,160 | $30,500 | Not Implemented |
CO0625 # 04 Y:2009 | 04 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $680 | $2,020 | Not Implemented |
CO0625 # 05 Y:2009 | 05 | 2009 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $110 | $210 | Not Implemented |
CO0541 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,670 | $8,550 | Not Implemented |
CO0541 # 06 Y:2004 | 06 | 2004 | USE PHOTOCELL CONTROLS | $740 | $510 | Not Implemented |
CO0541 # 04 Y:2004 | 04 | 2004 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $380 | $310 | Not Implemented |
CO0541 # 03 Y:2004 | 03 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $810 | $350 | Not Implemented |
CO0541 # 02 Y:2004 | 02 | 2004 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,070 | $560 | Not Implemented |