Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
36
matching recommendationsNAICS | 323111 | Commercial Printing (except Screen and Books) |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0177 # 04 Y:2017 | 04 | 2017 | INSTALL / REPAIR INSULATION ON STEAM LINES | $39,860 | $40,000 | Not Implemented |
DL0177 # 03 Y:2017 | 03 | 2017 | REPAIR AND ELIMINATE STEAM LEAKS | $12,079 | $3,000 | Not Implemented |
DL0177 # 01 Y:2017 | 01 | 2017 | OPERATE BOILERS ON HIGH FIRE SETTING | $16,174 | $28,750 | Not Implemented |
DL0177 # 02 Y:2017 | 02 | 2017 | INSTALL / REPAIR INSULATION ON STEAM LINES | $10,881 | $2,032 | Not Implemented |
DL0027 # 01 Y:2008 | 01 | 2008 | TURN OFF EQUIPMENT WHEN NOT IN USE | $8,800 | $0 | Implemented |
DL0027 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,691 | $27,814 | Not Implemented |
DL0027 # 03 Y:2008 | 03 | 2008 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,514 | $52,000 | Implemented |
DL0002 # 02 Y:2007 | 02 | 2007 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $49,771 | $62,783 | Not Implemented |
DL0002 # 01 Y:2007 | 01 | 2007 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $21,414 | $10,000 | Not Implemented |
DL0002 # 04 Y:2007 | 04 | 2007 | USE SOLAR HEAT TO HEAT MAKE-UP AIR | $20,592 | $100,100 | Not Implemented |
DL0002 # 03 Y:2007 | 03 | 2007 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $19,418 | $73,950 | Not Implemented |
WV0352 # 12 Y:2006 | 12 | 2006 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $325 | $38 | Not Implemented |
WV0352 # 11 Y:2006 | 11 | 2006 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $460 | $735 | Not Implemented |
WV0352 # 10 Y:2006 | 10 | 2006 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $473 | $325 | Not Implemented |
WV0352 # 09 Y:2006 | 09 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $702 | $13 | Not Implemented |
WV0352 # 08 Y:2006 | 08 | 2006 | INSTALL OCCUPANCY SENSORS | $857 | $700 | Not Implemented |
WV0352 # 07 Y:2006 | 07 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $857 | $25 | Not Implemented |
WV0352 # 06 Y:2006 | 06 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,241 | $1,335 | Implemented |
WV0352 # 05 Y:2006 | 05 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,773 | $1,431 | Implemented |
WV0352 # 04 Y:2006 | 04 | 2006 | DISCONNECT BALLASTS | $1,803 | $1,500 | Implemented |
WV0352 # 03 Y:2006 | 03 | 2006 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $1,862 | $3,440 | Implemented |
WV0352 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,003 | $15,353 | Not Implemented |
WV0352 # 01 Y:2006 | 01 | 2006 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,713 | $170 | Implemented |
WV0351 # 13 Y:2006 | 13 | 2006 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $398 | $7 | Not Implemented |
WV0351 # 12 Y:2006 | 12 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $630 | $1,336 | Not Implemented |