Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
204
matching recommendationsNAICS | 3311 | Iron and Steel Mills and Ferroalloy Manufacturing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0808 # 01 Y:2009 | 01 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $200,411 | $425,000 | Not Implemented |
UD0808 # 02 Y:2009 | 02 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $108,914 | $25,000 | Not Implemented |
UD0808 # 03 Y:2009 | 03 | 2009 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $95,164 | $300,000 | Not Implemented |
UD0808 # 04 Y:2009 | 04 | 2009 | OPTIMIZE PLANT POWER FACTOR | $74,208 | $223,000 | Not Implemented |
UD0808 # 05 Y:2009 | 05 | 2009 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $68,888 | $60,000 | Not Implemented |
UD0808 # 06 Y:2009 | 06 | 2009 | CONVERT FROM INDIRECT TO DIRECT FIRED SYSTEMS | $67,977 | $135,954 | Not Implemented |
UD0808 # 07 Y:2009 | 07 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $43,538 | $59,100 | Not Implemented |
UD0808 # 08 Y:2009 | 08 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $43,197 | $23,136 | Not Implemented |
UD0808 # 09 Y:2009 | 09 | 2009 | COVER OPEN TANKS | $25,313 | $0 | Not Implemented |
UD0808 # 10 Y:2009 | 10 | 2009 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $22,771 | $1,840 | Not Implemented |
UD0808 # 11 Y:2009 | 11 | 2009 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $18,970 | $20,000 | Not Implemented |
UD0808 # 12 Y:2009 | 12 | 2009 | UPGRADE CONTROLS ON COMPRESSORS | $17,167 | $0 | Not Implemented |
UD0808 # 13 Y:2009 | 13 | 2009 | INSULATE BARE EQUIPMENT | $15,493 | $33,695 | Not Implemented |
UD0808 # 14 Y:2009 | 14 | 2009 | INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN | $10,381 | $34,730 | Not Implemented |
UD0808 # 15 Y:2009 | 15 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,291 | $17,933 | Not Implemented |
UD0808 # 16 Y:2009 | 16 | 2009 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,446 | $1,000 | Implemented |
UD0808 # 17 Y:2009 | 17 | 2009 | INSULATE BARE EQUIPMENT | $8,068 | $11,383 | Not Implemented |
UD0808 # 18 Y:2009 | 18 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $7,518 | $21,818 | Not Implemented |
UD0808 # 19 Y:2009 | 19 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,269 | $20,543 | Not Implemented |
UD0808 # 20 Y:2009 | 20 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,344 | $7,155 | Not Implemented |
UD0808 # 21 Y:2009 | 21 | 2009 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,836 | $0 | Implemented |
UD0808 # 22 Y:2009 | 22 | 2009 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $3,305 | $18,884 | Not Implemented |
UD0808 # 23 Y:2009 | 23 | 2009 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,412 | $5,050 | Not Implemented |
UD0808 # 24 Y:2009 | 24 | 2009 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,053 | $0 | Not Implemented |
UD0808 # 25 Y:2009 | 25 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,670 | $0 | Not Implemented |